Refine your search

10 vulnerabilities found for HG9 by Tenda

CVE-2026-104610 (GCVE-0-2026-104610)
Vulnerability from cvelistv5
Published
2026-10-02 12:00
Modified
2026-10-02 13:50
CWE
Summary
A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
References
https://vuldb.com/vuln/412917 vdb-entry, technical-description
https://vuldb.com/vuln/412917/cti signature, permissions-required
https://vuldb.com/cve/CVE-2026-104610 third-party-advisory
https://vuldb.com/submit/962541 third-party-advisory
https://github.com/Expl0rer-Ct/CVE/issues/1 exploit, issue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG7 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG9 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG10 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-104610",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-02T13:49:47.985467Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-02T13:50:12.393Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Boa Web Server"
          ],
          "product": "HG7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Boa Web Server"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Boa Web Server"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Expl0rer.Ct (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-02T12:00:18.544Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-412917 | Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/412917"
        },
        {
          "name": "VDB-412917 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/412917/cti"
        },
        {
          "name": "CVE-2026-104610 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-104610"
        },
        {
          "name": "Submit #962541 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/962541"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/Expl0rer-Ct/CVE/issues/1"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-10-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-10-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-02T05:54:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-104610",
    "datePublished": "2026-10-02T12:00:18.544Z",
    "dateReserved": "2026-10-02T03:49:26.992Z",
    "dateUpdated": "2026-10-02T13:50:12.393Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11553 (GCVE-0-2026-11553)
Vulnerability from cvelistv5
Published
2026-06-08 17:15
Modified
2026-10-02 03:49
CWE
Summary
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
Impacted products
Vendor Product Version
Tenda HG7 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG9 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG10 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11553",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T18:49:04.954919Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T18:49:14.135Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "zhihua xie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-02T03:49:03.652Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369163 | Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369163"
        },
        {
          "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369163/cti"
        },
        {
          "name": "CVE-2026-11553 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11553"
        },
        {
          "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836778"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-02T05:53:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11553",
    "datePublished": "2026-06-08T17:15:11.855Z",
    "dateReserved": "2026-06-08T05:43:31.214Z",
    "dateUpdated": "2026-10-02T03:49:03.652Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11499 (GCVE-0-2026-11499)
Vulnerability from cvelistv5
Published
2026-06-08 07:00
Modified
2026-10-02 03:48
CWE
Summary
A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
References
Impacted products
Vendor Product Version
Tenda HG7 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG9 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG10 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11499",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:55:19.613788Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T12:55:29.374Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-02T03:48:57.001Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369119 | Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369119"
        },
        {
          "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369119/cti"
        },
        {
          "name": "CVE-2026-11499 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11499"
        },
        {
          "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834888"
        },
        {
          "name": "Submit #888875 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/888875"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-02T05:53:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11499",
    "datePublished": "2026-06-08T07:00:23.672Z",
    "dateReserved": "2026-06-07T13:23:38.138Z",
    "dateUpdated": "2026-10-02T03:48:57.001Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11498 (GCVE-0-2026-11498)
Vulnerability from cvelistv5
Published
2026-06-08 06:45
Modified
2026-10-02 03:48
CWE
Summary
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
References
Impacted products
Vendor Product Version
Tenda HG7 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG9 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
   Tenda HG10 Version: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11498",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:47:31.920390Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T16:22:24.244Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-02T03:48:52.157Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369118 | Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369118"
        },
        {
          "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369118/cti"
        },
        {
          "name": "CVE-2026-11498 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11498"
        },
        {
          "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834887"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-02T05:53:37.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11498",
    "datePublished": "2026-06-08T06:45:21.289Z",
    "dateReserved": "2026-06-07T13:22:12.336Z",
    "dateUpdated": "2026-10-02T03:48:52.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2910 (GCVE-0-2026-2910)
Vulnerability from cvelistv5
Published
2026-02-22 02:32
Modified
2026-02-23 19:17
CWE
Summary
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
References
https://vuldb.com/?id.347219 vdb-entry, technical-description
https://vuldb.com/?ctiid.347219 signature, permissions-required
https://vuldb.com/?submit.755212 third-party-advisory
https://github.com/QIU-DIE/cve-nneeww/issues/12 exploit, issue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG9 Version: 300001138
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2910",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-23T19:17:14.139751Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-23T19:17:27.114Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LINXI666 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-22T02:32:11.075Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.347219"
        },
        {
          "name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.347219"
        },
        {
          "name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.755212"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-02-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-02-20T21:20:04.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG9 formPing6 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-2910",
    "datePublished": "2026-02-22T02:32:11.075Z",
    "dateReserved": "2026-02-20T20:14:51.686Z",
    "dateUpdated": "2026-02-23T19:17:27.114Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2909 (GCVE-0-2026-2909)
Vulnerability from cvelistv5
Published
2026-02-22 02:02
Modified
2026-02-23 19:18
CWE
Summary
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
References
https://vuldb.com/?id.347218 vdb-entry, technical-description
https://vuldb.com/?ctiid.347218 signature, permissions-required
https://vuldb.com/?submit.755211 third-party-advisory
https://github.com/QIU-DIE/cve-nneeww/issues/11 exploit, issue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG9 Version: 300001138
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2909",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-23T19:18:27.278329Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-23T19:18:40.226Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Diagnostic Ping Endpoint"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LINXI666 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-22T02:02:14.122Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.347218"
        },
        {
          "name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.347218"
        },
        {
          "name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.755211"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-02-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-02-20T21:20:02.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-2909",
    "datePublished": "2026-02-22T02:02:14.122Z",
    "dateReserved": "2026-02-20T20:14:48.904Z",
    "dateUpdated": "2026-02-23T19:18:40.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2908 (GCVE-0-2026-2908)
Vulnerability from cvelistv5
Published
2026-02-22 02:02
Modified
2026-02-23 19:19
CWE
Summary
A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
References
https://vuldb.com/?id.347217 vdb-entry, technical-description
https://vuldb.com/?ctiid.347217 signature, permissions-required
https://vuldb.com/?submit.755202 third-party-advisory
https://github.com/QIU-DIE/cve-nneeww/issues/10 exploit, issue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG9 Version: 300001138
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2908",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-23T19:19:17.915757Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-23T19:19:51.049Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Loopback Detection Configuration Endpoint"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LINXI666 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-22T02:02:10.921Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.347217"
        },
        {
          "name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.347217"
        },
        {
          "name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.755202"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-02-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-02-20T21:20:00.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-2908",
    "datePublished": "2026-02-22T02:02:10.921Z",
    "dateReserved": "2026-02-20T20:14:45.983Z",
    "dateUpdated": "2026-02-23T19:19:51.049Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2907 (GCVE-0-2026-2907)
Vulnerability from cvelistv5
Published
2026-02-22 01:32
Modified
2026-02-23 19:23
CWE
Summary
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
References
https://vuldb.com/?id.347216 vdb-entry, technical-description
https://vuldb.com/?ctiid.347216 signature, permissions-required
https://vuldb.com/?submit.755201 third-party-advisory
https://github.com/QIU-DIE/cve-nneeww/issues/9 exploit, issue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG9 Version: 300001138
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2907",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-23T19:22:46.303895Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-23T19:23:03.755Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "GPON Configuration Endpoint"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LINXI666 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-22T01:32:12.542Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.347216"
        },
        {
          "name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.347216"
        },
        {
          "name": "Submit #755201 | Tenda HG9  V300001138 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.755201"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-02-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-02-20T21:19:59.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-2907",
    "datePublished": "2026-02-22T01:32:12.542Z",
    "dateReserved": "2026-02-20T20:14:43.142Z",
    "dateUpdated": "2026-02-23T19:23:03.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2906 (GCVE-0-2026-2906)
Vulnerability from cvelistv5
Published
2026-02-22 01:32
Modified
2026-02-24 15:38
CWE
Summary
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
References
https://vuldb.com/?id.347215 vdb-entry, technical-description
https://vuldb.com/?ctiid.347215 signature, permissions-required
https://vuldb.com/?submit.755193 third-party-advisory
https://github.com/QIU-DIE/cve-nneeww/issues/8 exploit, issue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG9 Version: 300001138
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2906",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-24T15:38:13.838475Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-24T15:38:54.600Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Samba Configuration Endpoint"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LINXI666 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-22T01:32:09.390Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.347215"
        },
        {
          "name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.347215"
        },
        {
          "name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.755193"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-02-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-02-20T21:19:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-2906",
    "datePublished": "2026-02-22T01:32:09.390Z",
    "dateReserved": "2026-02-20T20:14:40.341Z",
    "dateUpdated": "2026-02-24T15:38:54.600Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-2905 (GCVE-0-2026-2905)
Vulnerability from cvelistv5
Published
2026-02-22 01:02
Modified
2026-02-23 19:13
CWE
Summary
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
References
https://vuldb.com/?id.347214 vdb-entry, technical-description
https://vuldb.com/?ctiid.347214 signature, permissions-required
https://vuldb.com/?submit.755167 third-party-advisory
https://github.com/QIU-DIE/cve-nneeww/issues/7 exploit, issue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG9 Version: 300001138
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-2905",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-23T19:13:05.204806Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-23T19:13:59.154Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Wireless Configuration Endpoint"
          ],
          "product": "HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LINXI666 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-22T01:02:10.433Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.347214"
        },
        {
          "name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.347214"
        },
        {
          "name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.755167"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-02-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-02-20T21:19:56.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-2905",
    "datePublished": "2026-02-22T01:02:10.433Z",
    "dateReserved": "2026-02-20T20:14:32.380Z",
    "dateUpdated": "2026-02-23T19:13:59.154Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}