Refine your search

1 vulnerability found for HCL iControl by HCL

CVE-2025-62347 (GCVE-0-2025-62347)
Vulnerability from cvelistv5
Published
2026-07-31 15:16
Modified
2026-07-31 17:39
CWE
  • CWE-20 - Improper Input Validation
Summary
HCL iControl was affected by Improper Input Validation vulnerability. It is vulnerable to unexpected system behavior and potential security bypasses. This was caused by an implementation flaw in an architectural security tactic that fails to properly validate whether the received input matches the expected type.
Impacted products
Vendor Product Version
HCL HCL iControl Version: 4.3.0 and 4.4.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-62347",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-31T17:39:34.309611Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-31T17:39:58.918Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "HCL iControl",
          "vendor": "HCL",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.0 and 4.4.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u0026nbsp;HCL iControl was affected by Improper Input Validation vulnerability. It is vulnerable to unexpected system behavior and potential security bypasses. This was caused by an implementation flaw in an architectural security tactic that fails to properly validate whether the received input matches the expected type.\u0026nbsp;"
            }
          ],
          "value": "HCL iControl was affected by Improper Input Validation vulnerability. It is vulnerable to unexpected system behavior and potential security bypasses. This was caused by an implementation flaw in an architectural security tactic that fails to properly validate whether the received input matches the expected type."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-31T15:16:02.020Z",
        "orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
        "shortName": "HCL"
      },
      "references": [
        {
          "url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0132395"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
    "assignerShortName": "HCL",
    "cveId": "CVE-2025-62347",
    "datePublished": "2026-07-31T15:16:02.020Z",
    "dateReserved": "2025-10-10T09:04:27.772Z",
    "dateUpdated": "2026-07-31T17:39:58.918Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}