Refine your search

3 vulnerabilities found for EdgeMAX EdgeSwitch by Ubiquiti Inc

CVE-2026-77532 (GCVE-0-2026-77532)
Vulnerability from cvelistv5
Published
2026-08-26 11:01
Modified
2026-08-26 12:36
Severity ?
CWE
  • CWE-122 - Heap-based buffer overflow
Summary
A malicious actor with access to an adjacent network could exploit a Buffer Overflow vulnerability found in a DHCPv6-enabled EdgeMAX EdgeSwitch to initiate a Remote Code Execution on such device.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-77532",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-26T12:31:49.192604Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-26T12:36:20.285Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EdgeMAX EdgeSwitch",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.12.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A malicious actor with access to an adjacent network could exploit a Buffer Overflow vulnerability found in a DHCPv6-enabled EdgeMAX EdgeSwitch to initiate a Remote Code Execution on such device."
            }
          ],
          "value": "A malicious actor with access to an adjacent network could exploit a Buffer Overflow vulnerability found in a DHCPv6-enabled EdgeMAX EdgeSwitch to initiate a Remote Code Execution on such device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-based buffer overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-26T11:01:30.309Z",
        "orgId": "fe490ce8-0395-4072-90d8-2707e1bdf984",
        "shortName": "Ubiquiti"
      },
      "references": [
        {
          "url": "https://uisp.community.ui.com/releases/Security-Advisory-Bulletin-068-068/b95ea5e8-1a80-4ffc-ad42-625eae300cc9"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "fe490ce8-0395-4072-90d8-2707e1bdf984",
    "assignerShortName": "Ubiquiti",
    "cveId": "CVE-2026-77532",
    "datePublished": "2026-08-26T11:01:30.309Z",
    "dateReserved": "2026-08-20T20:26:31.514Z",
    "dateUpdated": "2026-08-26T12:36:20.285Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-48978 (GCVE-0-2025-48978)
Vulnerability from cvelistv5
Published
2025-08-21 00:01
Modified
2025-08-21 14:16
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later.
Impacted products
Vendor Product Version
Ubiquiti Inc EdgeMAX EdgeSwitch Version: 1.11.1   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-48978",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-21T14:15:24.082992Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-21T14:16:25.992Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EdgeMAX EdgeSwitch",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.11.1",
              "status": "affected",
              "version": "1.11.1",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.\r\n\r\nAffected Products:\r\n\r\nEdgeMAX EdgeSwitch (Version 1.11.0 and earlier) \r\n\r\n  \r\n\r\nMitigation:\r\n\r\nUpdate the EdgeMAX EdgeSwitch to Version 1.11.1 or later."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-21T00:01:24.208Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://community.ui.com/releases/Security-Advisory-Bulletin-054-054/3033f0b7-aca6-4d70-8c51-d3e706bd0ca7"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2025-48978",
    "datePublished": "2025-08-21T00:01:24.208Z",
    "dateReserved": "2025-05-29T15:00:04.772Z",
    "dateUpdated": "2025-08-21T14:16:25.992Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27211 (GCVE-0-2025-27211)
Vulnerability from cvelistv5
Published
2025-08-04 22:12
Modified
2025-08-05 13:26
Summary
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-27211",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-05T13:22:10.644805Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          },
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-05T13:26:05.845Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "EdgeMAX EdgeSwitch",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.11.0",
              "status": "unaffected",
              "version": "1.11.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-04T22:12:18.821Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2025-27211",
    "datePublished": "2025-08-04T22:12:18.821Z",
    "dateReserved": "2025-02-20T01:00:01.799Z",
    "dateUpdated": "2025-08-05T13:26:05.845Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}