4 vulnerabilities found for ENERGY METER 750-230 (2540910000) by Weidmueller
CVE-2025-41712 (GCVE-0-2025-41712)
Vulnerability from cvelistv5
Published
2026-03-10 08:27
Modified
2026-03-10 16:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Janitza | UMG 96RM-E 24V(5222063) |
Version: 0.0 < |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41712",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:35:50.983890Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T16:51:35.020Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 24V(5222063)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 230V(5222062)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-230 (2540910000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-24 (2540900000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Deutsche Telekom Security (DT Security)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T08:27:10.120Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-079/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-096/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Incorrect Permission Assignment on power analyzer",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41712",
"datePublished": "2026-03-10T08:27:10.120Z",
"dateReserved": "2025-04-16T11:17:48.311Z",
"dateUpdated": "2026-03-10T16:51:35.020Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41711 (GCVE-0-2025-41711)
Vulnerability from cvelistv5
Published
2026-03-10 08:26
Modified
2026-03-10 16:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Summary
An unauthenticated remote attacker can use firmware images to extract password hashes and brute force plaintext passwords of accounts with limited access.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Janitza | UMG 96RM-E 24V(5222063) |
Version: 0.0 < |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41711",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:57:57.426147Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T16:51:40.984Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 24V(5222063)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 230V(5222062)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-230 (2540910000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-24 (2540900000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Deutsche Telekom Security (DT Security)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn unauthenticated remote attacker can use firmware images to extract password hashes and brute force plaintext passwords of accounts with limited access.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can use firmware images to extract password hashes and brute force plaintext passwords of accounts with limited access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T08:26:48.759Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-079/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-096/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of a Broken or Risky Cryptographic Algorithm for firmware images of power analyzer",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41711",
"datePublished": "2026-03-10T08:26:48.759Z",
"dateReserved": "2025-04-16T11:17:48.311Z",
"dateUpdated": "2026-03-10T16:51:40.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41710 (GCVE-0-2025-41710)
Vulnerability from cvelistv5
Published
2026-03-10 08:26
Modified
2026-03-10 16:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Summary
An unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Janitza | UMG 96RM-E 24V(5222063) |
Version: 0.0 < |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41710",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:57:59.951313Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T16:51:47.193Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 24V(5222063)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 230V(5222062)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-230 (2540910000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-24 (2540900000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Deutsche Telekom Security (DT Security)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T08:26:30.909Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-079/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-096/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of Hard-coded Credentials in power analyzer",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41710",
"datePublished": "2026-03-10T08:26:30.909Z",
"dateReserved": "2025-04-16T11:17:48.311Z",
"dateUpdated": "2026-03-10T16:51:47.193Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41709 (GCVE-0-2025-41709)
Vulnerability from cvelistv5
Published
2026-03-10 08:26
Modified
2026-03-18 08:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Janitza | UMG 96RM-E 24V(5222063) |
Version: 0.0 < |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41709",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:58:49.458010Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T16:51:53.333Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 24V(5222063)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UMG 96RM-E 230V(5222062)",
"vendor": "Janitza",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-230 (2540910000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ENERGY METER 750-24 (2540900000)",
"vendor": "Weidmueller",
"versions": [
{
"lessThanOrEqual": "3.13",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Deutsche Telekom Security (DT Security)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-18T08:16:28.698Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-079/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://certvde.com/en/advisories/VDE-2025-096/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://janitza.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-079.json"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2025-096.json"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Command injection in power analyzer via Modbus-TCP and Modbus-RTU",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41709",
"datePublished": "2026-03-10T08:26:14.936Z",
"dateReserved": "2025-04-16T11:17:48.311Z",
"dateUpdated": "2026-03-18T08:16:28.698Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}