Refine your search

3 vulnerabilities found for Control System by Hydrosystem

CVE-2026-34185 (GCVE-0-2026-34185)
Vulnerability from cvelistv5
Published
2026-04-09 09:41
Modified
2026-04-09 11:45
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
Hydrosystem Control System is vulnerable to SQL Injection across most scripts and input parameters. Because no protections are in place, an authenticated attacker can inject arbitrary SQL commands, potentially gaining full control over the database.This issue was fixed in Hydrosystem Control System version 9.8.5
References
Impacted products
Vendor Product Version
Hydrosystem Control System Version: 0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-34185",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-09T11:45:27.662452Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-09T11:45:33.927Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Control System",
          "vendor": "Hydrosystem",
          "versions": [
            {
              "lessThan": "9.8.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jaros\u0142aw \"Jahrek\" Kami\u0144ski - Securitum"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Hydrosystem Control System is vulnerable to SQL Injection across most scripts and input parameters. Because no protections are in place, an authenticated attacker can inject arbitrary SQL commands, potentially gaining full control over the database.\u003cp\u003eThis issue was fixed in Hydrosystem Control System version 9.8.5\u003c/p\u003e"
            }
          ],
          "value": "Hydrosystem Control System is vulnerable to SQL Injection across most scripts and input parameters. Because no protections are in place, an authenticated attacker can inject arbitrary SQL commands, potentially gaining full control over the database.This issue was fixed in Hydrosystem Control System version 9.8.5"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-09T09:41:15.531Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/posts/2026/04/CVE-2026-4901/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.hydrosystem.poznan.pl/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "SQL Injection in Hydrosystem Control System",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2026-34185",
    "datePublished": "2026-04-09T09:41:15.531Z",
    "dateReserved": "2026-03-26T09:40:20.576Z",
    "dateUpdated": "2026-04-09T11:45:33.927Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-34184 (GCVE-0-2026-34184)
Vulnerability from cvelistv5
Published
2026-04-09 09:41
Modified
2026-04-09 11:51
CWE
Summary
Hydrosystem Control System does not enforce authorization for some directories. This allows an unauthorized attacker to read all files in these directories and even execute some of them. Critically the attacker could run PHP scripts directly on the connected database.This issue was fixed in Hydrosystem Control System version 9.8.5
References
Impacted products
Vendor Product Version
Hydrosystem Control System Version: 0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-34184",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-09T11:50:57.016464Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-09T11:51:07.882Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Control System",
          "vendor": "Hydrosystem",
          "versions": [
            {
              "lessThan": "9.8.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jaros\u0142aw \"Jahrek\" Kami\u0144ski - Securitum"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Hydrosystem Control System does not enforce authorization for some directories. This allows an unauthorized attacker to read all files in these directories and even execute some of them. Critically the attacker could run PHP scripts directly on the connected database.\u003cp\u003eThis issue was fixed in\u0026nbsp;Hydrosystem Control System version\u0026nbsp;9.8.5\u003c/p\u003e"
            }
          ],
          "value": "Hydrosystem Control System does not enforce authorization for some directories. This allows an unauthorized attacker to read all files in these directories and even execute some of them. Critically the attacker could run PHP scripts directly on the connected database.This issue was fixed in\u00a0Hydrosystem Control System version\u00a09.8.5"
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862: Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-09T09:41:08.526Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/posts/2026/04/CVE-2026-4901/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.hydrosystem.poznan.pl/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Missing Authorization in Hydrosystem Control System",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2026-34184",
    "datePublished": "2026-04-09T09:41:08.526Z",
    "dateReserved": "2026-03-26T09:40:20.576Z",
    "dateUpdated": "2026-04-09T11:51:07.882Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-4901 (GCVE-0-2026-4901)
Vulnerability from cvelistv5
Published
2026-04-09 09:40
Modified
2026-04-09 11:51
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Summary
Hydrosystem Control System saves sensitive information into a log file. Critically, user credentials are logged allowing the attacker to obtain further authorized access into the system. Combined with vulnerability CVE-2026-34184, these sensitive information could be accessed by an unauthorized user.This issue was fixed in Hydrosystem Control System version 9.8.5
References
Impacted products
Vendor Product Version
Hydrosystem Control System Version: 0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-4901",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-09T11:51:43.520510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-09T11:51:48.409Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Control System",
          "vendor": "Hydrosystem",
          "versions": [
            {
              "lessThan": "9.8.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jaros\u0142aw \"Jahrek\" Kami\u0144ski - Securitum"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Hydrosystem Control System saves sensitive information into a log file. Critically, user credentials are logged allowing the attacker to obtain further authorized access into the system. C\u003cspan style=\"background-color: rgba(214, 214, 214, 0.1);\"\u003eombined with vulnerability CVE-2026-34184, these sensitive information could be accessed by an unauthorized user.\u003c/span\u003e\u003cp\u003eThis issue was fixed in Hydrosystem Control System version 9.8.5\u003c/p\u003e"
            }
          ],
          "value": "Hydrosystem Control System saves sensitive information into a log file. Critically, user credentials are logged allowing the attacker to obtain further authorized access into the system. Combined with vulnerability CVE-2026-34184, these sensitive information could be accessed by an unauthorized user.This issue was fixed in Hydrosystem Control System version 9.8.5"
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-09T09:40:59.143Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/posts/2026/04/CVE-2026-4901/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.hydrosystem.poznan.pl/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Insertion of Sesitive Information into Log File in Hydrosystem Control System",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2026-4901",
    "datePublished": "2026-04-09T09:40:59.143Z",
    "dateReserved": "2026-03-26T14:59:49.077Z",
    "dateUpdated": "2026-04-09T11:51:48.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",