Refine your search

8 vulnerabilities found for CPP Firmware by Bosch

CVE-2021-23851 (GCVE-0-2021-23851)
Vulnerability from cvelistv5
Published
2022-03-30 16:03
Modified
2024-09-16 18:39
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A specially crafted TCP/IP packet may cause the camera recovery image web interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.460Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP4, CPP6, CPP7, CPP7.3"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A specially crafted TCP/IP packet may cause the camera recovery image web interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T16:03:04.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "UNKNOWN"
      },
      "title": "Buffer Overflow vulnerability in the recovery image web-based interface",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23851",
          "STATE": "PUBLIC",
          "TITLE": "Buffer Overflow vulnerability in the recovery image web-based interface"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP4, CPP6, CPP7, CPP7.3",
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A specially crafted TCP/IP packet may cause the camera recovery image web interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23851",
    "datePublished": "2022-03-30T16:03:04.883Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T18:39:12.509Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23850 (GCVE-0-2021-23850)
Vulnerability from cvelistv5
Published
2022-03-30 16:03
Modified
2024-09-17 02:57
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A specially crafted TCP/IP packet may cause a camera recovery image telnet interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.385Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP4, CPP6, CPP7, CPP7.3"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A specially crafted TCP/IP packet may cause a camera recovery image telnet interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T16:03:03.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "UNKNOWN"
      },
      "title": "Buffer Overflow vulnerability in the recovery image telnet server",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23850",
          "STATE": "PUBLIC",
          "TITLE": "Buffer Overflow vulnerability in the recovery image telnet server"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP4, CPP6, CPP7, CPP7.3",
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A specially crafted TCP/IP packet may cause a camera recovery image telnet interface to crash. It may also cause a buffer overflow which could enable remote code execution. The recovery image can only be booted with administrative rights or with physical access to the camera and allows the upload of a new firmware in case of a damaged firmware."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23850",
    "datePublished": "2022-03-30T16:03:03.708Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:57:11.806Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23849 (GCVE-0-2021-23849)
Vulnerability from cvelistv5
Published
2021-08-05 19:23
Modified
2024-09-16 17:23
CWE
  • CWE-352 - Cross-Site Request Forgery (CSRF)
Summary
A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a malicious website while being logged in into the camera.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.380Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-033305-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP4, CPP6, AVIOTEC, CPP7, CPP7.3, CPP13, CPP14"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2021-08-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a malicious website while being logged in into the camera."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352 Cross-Site Request Forgery (CSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-05T19:23:32.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-033305-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "UNKNOWN"
      },
      "title": "Cross Site Request Forgery (CSRF) vulnerability in web based management interface",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-08-04",
          "ID": "CVE-2021-23849",
          "STATE": "PUBLIC",
          "TITLE": "Cross Site Request Forgery (CSRF) vulnerability in web based management interface"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP4, CPP6, AVIOTEC, CPP7, CPP7.3, CPP13, CPP14",
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a malicious website while being logged in into the camera."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-352 Cross-Site Request Forgery (CSRF)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-033305-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-033305-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23849",
    "datePublished": "2021-08-05T19:23:32.655Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:23:27.843Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23854 (GCVE-0-2021-23854)
Vulnerability from cvelistv5
Published
2021-06-09 14:20
Modified
2024-09-16 17:32
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected.
Impacted products
Vendor Product Version
Bosch CPP Firmware Version: 7.70
Version: 7.72
Version: 7.62
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.247Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP6, CPP7, CPP7.3"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "7.70"
            },
            {
              "status": "affected",
              "version": "7.72"
            },
            {
              "status": "affected",
              "version": "7.62"
            }
          ]
        },
        {
          "platforms": [
            "CPP13"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "7.75"
            },
            {
              "status": "affected",
              "version": "7.76"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T14:20:14.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "UNKNOWN"
      },
      "title": "Reflected XSS in page parameter",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23854",
          "STATE": "PUBLIC",
          "TITLE": "Reflected XSS in page parameter"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP6, CPP7, CPP7.3",
                            "version_affected": "=",
                            "version_value": "7.70"
                          },
                          {
                            "platform": "CPP6, CPP7, CPP7.3",
                            "version_affected": "=",
                            "version_value": "7.72"
                          },
                          {
                            "platform": "CPP6, CPP7, CPP7.3",
                            "version_affected": "=",
                            "version_value": "7.62"
                          },
                          {
                            "platform": "CPP13",
                            "version_affected": "=",
                            "version_value": "7.75"
                          },
                          {
                            "platform": "CPP13",
                            "version_affected": "=",
                            "version_value": "7.76"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23854",
    "datePublished": "2021-06-09T14:20:14.134Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:32:50.243Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23847 (GCVE-0-2021-23847)
Vulnerability from cvelistv5
Published
2021-06-09 14:19
Modified
2024-09-17 02:46
Severity ?
CWE
  • CWE-287 - Improper Authentication
Summary
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.
Impacted products
Vendor Product Version
Bosch CPP Firmware Version: 7.70
Version: 7.72
Version: unspecified   < 7.80 B128
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.274Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP6, CPP7, CPP7.3"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "7.70"
            },
            {
              "status": "affected",
              "version": "7.72"
            },
            {
              "lessThan": "7.80 B128",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T14:19:47.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "EXTERNAL"
      },
      "title": "Unauthenticated Information Extraction Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23847",
          "STATE": "PUBLIC",
          "TITLE": "Unauthenticated Information Extraction Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP6, CPP7, CPP7.3",
                            "version_affected": "=",
                            "version_value": "7.70"
                          },
                          {
                            "platform": "CPP6, CPP7, CPP7.3",
                            "version_affected": "=",
                            "version_value": "7.72"
                          },
                          {
                            "platform": "CPP6, CPP7, CPP7.3",
                            "version_affected": "\u003c",
                            "version_value": "7.80 B128"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287 Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23847",
    "datePublished": "2021-06-09T14:19:47.260Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:46:39.127Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23853 (GCVE-0-2021-23853)
Vulnerability from cvelistv5
Published
2021-06-09 14:19
Modified
2024-09-17 00:25
CWE
  • CWE-20 - Improper Input Validation
Summary
In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.733Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP4, CPP6, CPP7, CPP7.3, CPP13"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T14:19:24.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "UNKNOWN"
      },
      "title": "Improper Input Validation of HTTP Headers",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23853",
          "STATE": "PUBLIC",
          "TITLE": "Improper Input Validation of HTTP Headers"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP4, CPP6, CPP7, CPP7.3, CPP13",
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23853",
    "datePublished": "2021-06-09T14:19:24.674Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:25:32.494Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23848 (GCVE-0-2021-23848)
Vulnerability from cvelistv5
Published
2021-06-09 14:18
Modified
2024-09-16 16:27
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.760Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP4, CPP6, CPP7, CPP7.3, CPP13"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T14:18:46.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Reflected XSS in URL handler",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23848",
          "STATE": "PUBLIC",
          "TITLE": "Reflected XSS in URL handler"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP4, CPP6, CPP7, CPP7.3, CPP13",
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23848",
    "datePublished": "2021-06-09T14:18:46.544Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:27:51.671Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23852 (GCVE-0-2021-23852)
Vulnerability from cvelistv5
Published
2021-06-09 14:18
Modified
2024-09-16 22:03
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Summary
An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS).
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.365Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP4, CPP6, CPP7, CPP7.3, CPP13"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T14:18:24.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "UNKNOWN"
      },
      "title": "Denial of Service (DoS) due to invalid web parameter",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23852",
          "STATE": "PUBLIC",
          "TITLE": "Denial of Service (DoS) due to invalid web parameter"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP4, CPP6, CPP7, CPP7.3, CPP13",
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS)."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23852",
    "datePublished": "2021-06-09T14:18:24.707Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:03:24.110Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}