Refine your search
6 vulnerabilities found for CODESYS Virtual Control SL by CODESYS
CVE-2026-3509 (GCVE-0-2026-3509)
Vulnerability from cvelistv5
Published
2026-03-24 07:42
Modified
2026-03-26 12:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-134 - Use of Externally-Controlled Format String
Summary
An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial‑of‑service (DoS) condition.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Version: 3.5.17.0 ≤ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3509",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-26T12:35:33.893071Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-26T12:35:48.666Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial\u2011of\u2011service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial\u2011of\u2011service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134 Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:42:33.820Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-018"
}
],
"source": {
"advisory": "VDE-2026-018",
"defect": [
"CERT@VDE#641968"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Audit Log Format String DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-3509",
"datePublished": "2026-03-24T07:42:33.820Z",
"dateReserved": "2026-03-04T09:24:19.745Z",
"dateUpdated": "2026-03-26T12:35:48.666Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41660 (GCVE-0-2025-41660)
Vulnerability from cvelistv5
Published
2026-03-24 07:41
Modified
2026-03-24 13:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-669 - Incorrect Resource Transfer Between Spheres
Summary
A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Version: 0.0.0 ≤ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-24T13:15:49.570572Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T13:16:02.920Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Luca Borzacchiello from Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.\u003cbr\u003e"
}
],
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-669",
"description": "CWE-669 Incorrect Resource Transfer Between Spheres",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:41:43.004Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-011"
}
],
"source": {
"advisory": "VDE-2026-011",
"defect": [
"CERT@VDE#641802"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Boot Application Replacement Enables Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41660",
"datePublished": "2026-03-24T07:41:43.004Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2026-03-24T13:16:02.920Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41738 (GCVE-0-2025-41738)
Vulnerability from cvelistv5
Published
2025-12-01 10:02
Modified
2025-12-01 14:00
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41738",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T13:59:44.375519Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T14:00:28.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:02:33.407Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-100"
}
],
"source": {
"advisory": "VDE-2025-100",
"defect": [
"CERT@VDE#641889"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Invalid type usage in visualization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41738",
"datePublished": "2025-12-01T10:02:33.407Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2025-12-01T14:00:28.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41739 (GCVE-0-2025-41739)
Vulnerability from cvelistv5
Published
2025-12-01 10:00
Modified
2026-01-07 17:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS PLCHandler |
Version: 3.5.21.0 ≤ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41739",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T14:03:10.321003Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-07T17:09:52.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS PLCHandler",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Edge Gateway for Linux",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS TargetVisu for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB AG"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:00:44.373Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-099"
}
],
"source": {
"advisory": "VDE-2025-099",
"defect": [
"CERT@VDE#641888"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Linux/QNX SysSocket flaw",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41739",
"datePublished": "2025-12-01T10:00:44.373Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2026-01-07T17:09:52.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-0694 (GCVE-0-2025-0694)
Vulnerability from cvelistv5
Published
2025-03-18 11:04
Modified
2025-03-18 13:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Version: 0 ≤ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-18T13:09:24.499918Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T13:09:54.473Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "D. Blagojevic, S.Dietz and T. Weber from CyberDanube"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access."
}
],
"value": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T11:04:06.167Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2025-015"
}
],
"source": {
"advisory": "VDE-2025-015",
"defect": [
"CERT@VDE#641743"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control V3 removable media path traversal",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-0694",
"datePublished": "2025-03-18T11:04:06.167Z",
"dateReserved": "2025-01-24T08:27:09.159Z",
"dateUpdated": "2025-03-18T13:09:54.473Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8175 (GCVE-0-2024-8175)
Vulnerability from cvelistv5
Published
2024-09-25 08:04
Modified
2024-09-25 14:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Summary
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Version: 0 ≤ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_control_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T13:44:03.391474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T14:02:28.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T13:33:10.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"source": {
"advisory": "VDE-2024-057",
"defect": [
"CERT@VDE#641681"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: web server vulnerable to DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-8175",
"datePublished": "2024-09-25T08:04:23.196Z",
"dateReserved": "2024-08-26T09:58:34.794Z",
"dateUpdated": "2024-09-25T14:02:28.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}