Refine your search

2 vulnerabilities found for ASUS Business System Control Interface by ASUS

CVE-2025-15038 (GCVE-0-2025-15038)
Vulnerability from cvelistv5
Published
2026-03-12 02:03
Modified
2026-03-12 14:48
CWE
Summary
An Out-of-Bounds Read vulnerability exists in the ASUS Business System Control Interface driver. This vulnerability can be triggered by an unprivileged local user sending a specially crafted IOCTL  request, potentially leading to a disclosure of kernel information or a system crash. Refer to the "Security Update for ASUS  Business System Control Interface" section on the ASUS Security Advisory for more information.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-15038",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-12T14:47:20.773357Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-12T14:48:08.340Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ASUS Business System Control Interface",
          "vendor": "ASUS",
          "versions": [
            {
              "lessThan": "0.5.14.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:asus:asus_business_system_control_interface:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "0.5.14.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn Out-of-Bounds\nRead vulnerability exists in the ASUS Business System\nControl Interface driver. This vulnerability can be triggered by an unprivileged local  user\nsending a specially crafted IOCTL \u0026nbsp;request, potentially leading\nto a disclosure of\nkernel information or a system crash. Refer to the \"Security Update for ASUS\u0026nbsp;\nBusiness System Control Interface\" section on the ASUS Security Advisory for more information.\u003c/p\u003e"
            }
          ],
          "value": "An Out-of-Bounds\nRead vulnerability exists in the ASUS Business System\nControl Interface driver. This vulnerability can be triggered by an unprivileged local  user\nsending a specially crafted IOCTL \u00a0request, potentially leading\nto a disclosure of\nkernel information or a system crash. Refer to the \"Security Update for ASUS\u00a0\nBusiness System Control Interface\" section on the ASUS Security Advisory for more information."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-12T02:55:39.399Z",
        "orgId": "54bf65a7-a193-42d2-b1ba-8e150d3c35e1",
        "shortName": "ASUS"
      },
      "references": [
        {
          "url": "https://www.asus.com/content/security-advisory"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "54bf65a7-a193-42d2-b1ba-8e150d3c35e1",
    "assignerShortName": "ASUS",
    "cveId": "CVE-2025-15038",
    "datePublished": "2026-03-12T02:03:19.645Z",
    "dateReserved": "2025-12-23T06:48:58.144Z",
    "dateUpdated": "2026-03-12T14:48:08.340Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-15037 (GCVE-0-2025-15037)
Vulnerability from cvelistv5
Published
2026-03-12 02:00
Modified
2026-03-12 13:15
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
An Incorrect Permission Assignment vulnerability exists in the ASUS Business System Control Interface driver. This vulnerability can be triggered by an unprivileged local user sending a specially crafted IOCTL request, potentially leading to unauthorized access to sensitive hardware resources and kernel information disclosure. Refer to the "ASUS Business System Control Interface" section on the ASUS Security Advisory for more information.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-15037",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-12T13:15:48.452586Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-12T13:15:55.928Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ASUS Business System Control Interface",
          "vendor": "ASUS",
          "versions": [
            {
              "lessThan": "0.5.14.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:asus:asus_business_system_control_interface:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "0.5.14.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn Incorrect\nPermission Assignment vulnerability exists in the ASUS Business\nSystem Control Interface driver. This vulnerability can be triggered by an unprivileged local user sending a\nspecially crafted IOCTL request,\npotentially leading to unauthorized access to sensitive hardware resources\nand kernel information disclosure. Refer to the \"ASUS Business System Control Interface\" section on the ASUS Security Advisory for more information. \u003c/p\u003e"
            }
          ],
          "value": "An Incorrect\nPermission Assignment vulnerability exists in the ASUS Business\nSystem Control Interface driver. This vulnerability can be triggered by an unprivileged local user sending a\nspecially crafted IOCTL request,\npotentially leading to unauthorized access to sensitive hardware resources\nand kernel information disclosure. Refer to the \"ASUS Business System Control Interface\" section on the ASUS Security Advisory for more information."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-12T02:00:20.964Z",
        "orgId": "54bf65a7-a193-42d2-b1ba-8e150d3c35e1",
        "shortName": "ASUS"
      },
      "references": [
        {
          "url": "https://www.asus.com/content/security-advisory/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "54bf65a7-a193-42d2-b1ba-8e150d3c35e1",
    "assignerShortName": "ASUS",
    "cveId": "CVE-2025-15037",
    "datePublished": "2026-03-12T02:00:20.964Z",
    "dateReserved": "2025-12-23T06:48:49.410Z",
    "dateUpdated": "2026-03-12T13:15:55.928Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}