Refine your search

8 vulnerabilities found for AC500 by Tenda

CVE-2025-7586 (GCVE-0-2025-7586)
Vulnerability from cvelistv5
Published
2025-07-14 08:02
Modified
2025-07-14 15:22
CWE
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda AC500 Version: 2.0.1.9(1307)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7586",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-14T15:09:40.026670Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-14T15:22:29.586Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.9(1307)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "panda_0x1 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion formSetAPCfg der Datei /goform/setWtpData. Mit der Manipulation des Arguments radio_2g_1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-14T08:02:06.975Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-316285 | Tenda AC500 setWtpData formSetAPCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.316285"
        },
        {
          "name": "VDB-316285 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.316285"
        },
        {
          "name": "Submit #615169 | Tenda AC500 V2.0.1.9(1307) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.615169"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-13T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-13T15:03:11.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC500 setWtpData formSetAPCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-7586",
    "datePublished": "2025-07-14T08:02:06.975Z",
    "dateReserved": "2025-07-13T12:58:01.563Z",
    "dateUpdated": "2025-07-14T15:22:29.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from cvelistv5
Published
2024-10-23 13:31
Modified
2024-10-23 17:41
CWE
  • CWE-476 - NULL Pointer Dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.06"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.09"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.48.23"
              },
              {
                "status": "affected",
                "version": "16.03.48.19"
              },
              {
                "status": "affected",
                "version": "16.03.48.20"
              },
              {
                "status": "affected",
                "version": "16.03.48.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42"
              },
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318_\\)"
              },
              {
                "status": "affected",
                "version": "15.03.05.14"
              },
              {
                "status": "affected",
                "version": "15.03.2.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.9\\(1307\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.16"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.14"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10280",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:28:19.760214Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:41:57.370Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "minipython (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T13:31:07.315Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281555"
        },
        {
          "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281555"
        },
        {
          "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.426417"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:07:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10280",
    "datePublished": "2024-10-23T13:31:07.315Z",
    "dateReserved": "2024-10-23T06:02:03.363Z",
    "dateUpdated": "2024-10-23T17:41:57.370Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-3910 (GCVE-0-2024-3910)
Vulnerability from cvelistv5
Published
2024-04-17 12:00
Modified
2024-08-01 20:26
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Tenda AC500 Version: 2.0.1.9(1307)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3910",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-23T19:14:35.355698Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:33:24.339Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.124Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261146 | Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261146"
          },
          {
            "name": "VDB-261146 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261146"
          },
          {
            "name": "Submit #313805 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.313805"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.9(1307)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC500 2.0.1.9(1307) entdeckt. Es geht hierbei um die Funktion fromDhcpListClient der Datei /goform/DhcpListClient. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T12:00:05.651Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261146 | Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261146"
        },
        {
          "name": "VDB-261146 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261146"
        },
        {
          "name": "Submit #313805 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.313805"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-17T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-17T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-17T07:53:13.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-3910",
    "datePublished": "2024-04-17T12:00:05.651Z",
    "dateReserved": "2024-04-17T05:42:57.816Z",
    "dateUpdated": "2024-08-01T20:26:57.124Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-3909 (GCVE-0-2024-3909)
Vulnerability from cvelistv5
Published
2024-04-17 11:31
Modified
2024-08-01 20:26
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Tenda AC500 Version: 2.0.1.9(1307)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.9\\(1307\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3909",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-22T15:10:58.576153Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:31:11.551Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.136Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261145"
          },
          {
            "name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261145"
          },
          {
            "name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.313804"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.9(1307)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formexeCommand der Datei /goform/execCommand. Mittels dem Manipulieren des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T11:31:05.865Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261145"
        },
        {
          "name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261145"
        },
        {
          "name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.313804"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-17T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-17T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-17T07:53:08.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC500 execCommand formexeCommand stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-3909",
    "datePublished": "2024-04-17T11:31:05.865Z",
    "dateReserved": "2024-04-17T05:42:53.219Z",
    "dateUpdated": "2024-08-01T20:26:57.136Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-3908 (GCVE-0-2024-3908)
Vulnerability from cvelistv5
Published
2024-04-17 11:31
Modified
2024-08-01 20:26
CWE
Summary
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Tenda AC500 Version: 2.0.1.9(1307)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3908",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T19:08:58.012071Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:31:17.567Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.152Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261144 | Tenda AC500 WriteFacMac formWriteFacMac command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261144"
          },
          {
            "name": "VDB-261144 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261144"
          },
          {
            "name": "Submit #313803 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.313803"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.9(1307)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC500 2.0.1.9(1307) entdeckt. Betroffen hiervon ist die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Durch Manipulation des Arguments mac mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T11:31:04.525Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261144 | Tenda AC500 WriteFacMac formWriteFacMac command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261144"
        },
        {
          "name": "VDB-261144 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261144"
        },
        {
          "name": "Submit #313803 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.313803"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-17T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-17T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-17T07:53:05.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC500 WriteFacMac formWriteFacMac command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-3908",
    "datePublished": "2024-04-17T11:31:04.525Z",
    "dateReserved": "2024-04-17T05:42:48.926Z",
    "dateUpdated": "2024-08-01T20:26:57.152Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-3907 (GCVE-0-2024-3907)
Vulnerability from cvelistv5
Published
2024-04-17 11:00
Modified
2024-08-01 20:26
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Tenda AC500 Version: 2.0.1.9(1307)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "-2.0.1.9(1307)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3907",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-22T19:50:29.075942Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:32:54.186Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.130Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261143 | Tenda AC500 setcfm formSetCfm stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261143"
          },
          {
            "name": "VDB-261143 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261143"
          },
          {
            "name": "Submit #313802 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.313802"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.9(1307)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC500 2.0.1.9(1307) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formSetCfm der Datei /goform/setcfm. Durch die Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T11:00:06.424Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261143 | Tenda AC500 setcfm formSetCfm stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261143"
        },
        {
          "name": "VDB-261143 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261143"
        },
        {
          "name": "Submit #313802 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.313802"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-17T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-17T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-17T07:53:02.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC500 setcfm formSetCfm stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-3907",
    "datePublished": "2024-04-17T11:00:06.424Z",
    "dateReserved": "2024-04-17T05:42:46.647Z",
    "dateUpdated": "2024-08-01T20:26:57.130Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-3906 (GCVE-0-2024-3906)
Vulnerability from cvelistv5
Published
2024-04-17 10:31
Modified
2024-08-01 20:26
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
Tenda AC500 Version: 2.0.1.9(1307)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.9(1307)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3906",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-23T18:24:41.411561Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:33:20.174Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.104Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261142"
          },
          {
            "name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261142"
          },
          {
            "name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.313801"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.9(1307)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC500 2.0.1.9(1307) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Mit der Manipulation des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T10:31:05.641Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261142"
        },
        {
          "name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261142"
        },
        {
          "name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.313801"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-17T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-17T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-17T07:52:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC500 QuickIndex formQuickIndex stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-3906",
    "datePublished": "2024-04-17T10:31:05.641Z",
    "dateReserved": "2024-04-17T05:42:39.118Z",
    "dateUpdated": "2024-08-01T20:26:57.104Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-3905 (GCVE-0-2024-3905)
Vulnerability from cvelistv5
Published
2024-04-17 10:31
Modified
2024-08-01 20:26
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
Tenda AC500 Version: 2.0.1.9(1307)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3905",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T19:10:05.982005Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:31:03.283Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.134Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261141"
          },
          {
            "name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261141"
          },
          {
            "name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.313790"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.9(1307)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC500 2.0.1.9(1307) ausgemacht. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion R7WebsSecurityHandler der Datei /goform/execCommand. Dank Manipulation des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T10:31:04.297Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261141"
        },
        {
          "name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261141"
        },
        {
          "name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.313790"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-17T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-17T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-17T07:52:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-3905",
    "datePublished": "2024-04-17T10:31:04.297Z",
    "dateReserved": "2024-04-17T05:42:30.657Z",
    "dateUpdated": "2024-08-01T20:26:57.134Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}