Refine your search

8 vulnerabilities found for A950RG by TOTOLINK

CVE-2026-116508 (GCVE-0-2026-116508)
Vulnerability from cvelistv5
Published
2026-10-26 21:30
Modified
2026-10-26 21:30
CWE
Summary
A security flaw has been discovered in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected by this issue is the function sub_402340 of the file infostat.cgi of the component Device-Information CGI. Performing a manipulation of the argument CONTENT_LENGTH results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
References
Impacted products
Vendor Product Version
TOTOLINK A950RG Version: 4.1.2cu.5268_B20221104
    cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Device-Information CGI"
          ],
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5268_B20221104"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LiuYijun_JX.SGCC (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected by this issue is the function sub_402340 of the file infostat.cgi of the component Device-Information CGI. Performing a manipulation of the argument CONTENT_LENGTH results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-26T21:30:18.376Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-426406 | TOTOLINK A950RG Device-Information CGI infostat.cgi sub_402340 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/426406"
        },
        {
          "name": "VDB-426406 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/426406/cti"
        },
        {
          "name": "CVE-2026-116508 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-116508"
        },
        {
          "name": "Submit #1022557 | TOTOLINK A950RG V4.1.2cu.5268_B20221104 Stack Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/1022557"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gist.github.com/H3rmesk1t/ad72def4ccc232757d4cbabf45da72cb"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-10-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-10-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-26T14:19:09.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A950RG Device-Information CGI infostat.cgi sub_402340 stack-based overflow",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-116508",
    "datePublished": "2026-10-26T21:30:18.376Z",
    "dateReserved": "2026-10-26T13:13:43.963Z",
    "dateUpdated": "2026-10-26T21:30:18.376Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-116507 (GCVE-0-2026-116507)
Vulnerability from cvelistv5
Published
2026-10-26 21:15
Modified
2026-10-27 14:17
CWE
Summary
A vulnerability was identified in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected by this vulnerability is the function getLanguageCfg of the file global.so. Such manipulation of the argument token leads to information disclosure. The attack may be launched remotely. The exploit is publicly available and might be used.
References
Impacted products
Vendor Product Version
TOTOLINK A950RG Version: 4.1.2cu.5268_B20221104
    cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-116507",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-27T13:57:57.220628Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-27T14:17:44.541Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5268_B20221104"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LiuYijun_JX.SGCC (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected by this vulnerability is the function getLanguageCfg of the file global.so. Such manipulation of the argument token leads to information disclosure. The attack may be launched remotely. The exploit is publicly available and might be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "Information Disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "Improper Access Controls",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-26T21:15:18.291Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-426405 | TOTOLINK A950RG global.so getLanguageCfg information disclosure",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/426405"
        },
        {
          "name": "VDB-426405 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/426405/cti"
        },
        {
          "name": "CVE-2026-116507 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-116507"
        },
        {
          "name": "Submit #1022556 | TOTOLINK A950RG V4.1.2cu.5268_B20221104 Information Disclosure",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/1022556"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gist.github.com/H3rmesk1t/dd00f9b1c7b90a07c306ae369738f99f"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-10-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-10-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-26T14:19:04.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A950RG global.so getLanguageCfg information disclosure",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-116507",
    "datePublished": "2026-10-26T21:15:18.291Z",
    "dateReserved": "2026-10-26T13:13:40.442Z",
    "dateUpdated": "2026-10-27T14:17:44.541Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-116506 (GCVE-0-2026-116506)
Vulnerability from cvelistv5
Published
2026-10-26 21:00
Modified
2026-10-26 21:00
CWE
Summary
A vulnerability was determined in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected is the function apmib_set of the file firewall.so. This manipulation causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
References
Impacted products
Vendor Product Version
TOTOLINK A950RG Version: 4.1.2cu.5268_B20221104
    cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5268_B20221104"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LiuYijun_JX.SGCC (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected is the function apmib_set of the file firewall.so. This manipulation causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-26T21:00:16.563Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-426404 | TOTOLINK A950RG firewall.so apmib_set command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/426404"
        },
        {
          "name": "VDB-426404 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/426404/cti"
        },
        {
          "name": "CVE-2026-116506 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-116506"
        },
        {
          "name": "Submit #1022555 | TOTOLINK A950RG V4.1.2cu.5268_B20221104 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/1022555"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gist.github.com/H3rmesk1t/1046036a8601e93f375754e11307bfc8"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-10-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-10-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-26T14:18:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A950RG firewall.so apmib_set command injection",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-116506",
    "datePublished": "2026-10-26T21:00:16.563Z",
    "dateReserved": "2026-10-26T13:13:36.614Z",
    "dateUpdated": "2026-10-26T21:00:16.563Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-116505 (GCVE-0-2026-116505)
Vulnerability from cvelistv5
Published
2026-10-26 20:45
Modified
2026-10-26 20:45
CWE
Summary
A vulnerability was found in TOTOLINK A950RG 4.1.2cu.5268_B20221104. This impacts the function getDeviceInfo of the file /var/lib/misc/udhcpd.leases of the component device-information Handler. The manipulation of the argument MAC address results in command injection. The attack can be launched remotely. The exploit has been made public and could be used.
References
Impacted products
Vendor Product Version
TOTOLINK A950RG Version: 4.1.2cu.5268_B20221104
    cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "device-information Handler"
          ],
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5268_B20221104"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LiuYijun_JX.SGCC (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK A950RG 4.1.2cu.5268_B20221104. This impacts the function getDeviceInfo of the file /var/lib/misc/udhcpd.leases of the component device-information Handler. The manipulation of the argument MAC address results in command injection. The attack can be launched remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 8.3,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-26T20:45:18.066Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-426403 | TOTOLINK A950RG device-information udhcpd.leases getDeviceInfo command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/426403"
        },
        {
          "name": "VDB-426403 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/426403/cti"
        },
        {
          "name": "CVE-2026-116505 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-116505"
        },
        {
          "name": "Submit #1022554 | TOTOLINK A950RG V4.1.2cu.5268_B20221104 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/1022554"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gist.github.com/H3rmesk1t/836a8c4be24fcc4b7041b4bbe9cbb178"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-10-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-10-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-26T14:18:54.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A950RG device-information udhcpd.leases getDeviceInfo command injection",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-116505",
    "datePublished": "2026-10-26T20:45:18.066Z",
    "dateReserved": "2026-10-26T13:13:32.773Z",
    "dateUpdated": "2026-10-26T20:45:18.066Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-116504 (GCVE-0-2026-116504)
Vulnerability from cvelistv5
Published
2026-10-26 20:30
Modified
2026-10-27 14:18
CWE
Summary
A vulnerability has been found in TOTOLINK A950RG 4.1.2cu.5268_B20221104. This affects the function setCloudUpgradeFW of the file lib/cste_modules/upgrade.so of the component Cloud Upgrade. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
References
Impacted products
Vendor Product Version
TOTOLINK A950RG Version: 4.1.2cu.5268_B20221104
    cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-116504",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-27T14:06:36.678372Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-27T14:18:09.375Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Cloud Upgrade"
          ],
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5268_B20221104"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LiuYijun_JX.SGCC (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in TOTOLINK A950RG 4.1.2cu.5268_B20221104. This affects the function setCloudUpgradeFW of the file lib/cste_modules/upgrade.so of the component Cloud Upgrade. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-26T20:30:16.475Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-426402 | TOTOLINK A950RG Cloud Upgrade upgrade.so setCloudUpgradeFW command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/426402"
        },
        {
          "name": "VDB-426402 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/426402/cti"
        },
        {
          "name": "CVE-2026-116504 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-116504"
        },
        {
          "name": "Submit #1022553 | TOTOLINK A950RG V4.1.2cu.5268_B20221104 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/1022553"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gist.github.com/H3rmesk1t/c2f2dcfdb6238a7ddb8fb0622ad52948"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-10-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-10-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-26T14:18:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A950RG Cloud Upgrade upgrade.so setCloudUpgradeFW command injection",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-116504",
    "datePublished": "2026-10-26T20:30:16.475Z",
    "dateReserved": "2026-10-26T13:13:29.201Z",
    "dateUpdated": "2026-10-27T14:18:09.375Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-114575 (GCVE-0-2026-114575)
Vulnerability from cvelistv5
Published
2026-10-22 01:00
Modified
2026-10-28 18:42
CWE
Summary
A flaw has been found in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected by this issue is the function UploadCustomModule of the file lib/cste_modules/product.so. Executing a manipulation of the argument FileMd5 can lead to command injection. The attack can be launched remotely. The exploit has been published and may be used.
References
Impacted products
Vendor Product Version
TOTOLINK A950RG Version: 4.1.2cu.5268_B20221104
    cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-114575",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-28T18:38:25.760759Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-28T18:42:09.777Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:totolink:a950rg_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5268_B20221104"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "H3rmesk1t (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected by this issue is the function UploadCustomModule of the file lib/cste_modules/product.so. Executing a manipulation of the argument FileMd5 can lead to command injection. The attack can be launched remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-22T01:00:21.351Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-424943 | TOTOLINK A950RG product.so UploadCustomModule command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/424943"
        },
        {
          "name": "VDB-424943 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/424943/cti"
        },
        {
          "name": "CVE-2026-114575 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-114575"
        },
        {
          "name": "Submit #1021292 | TOTOLINK A950RG V4.1.2cu.5268_B20221104 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/1021292"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gist.github.com/H3rmesk1t/3a629799af33425e07571182e539a794"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-10-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-10-21T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-10-21T20:23:30.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A950RG product.so UploadCustomModule command injection",
      "x_generator": [
        "VulDB PVTS v202610"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-114575",
    "datePublished": "2026-10-22T01:00:21.351Z",
    "dateReserved": "2026-10-21T18:18:21.784Z",
    "dateUpdated": "2026-10-28T18:42:09.777Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-15271 (GCVE-0-2026-15271)
Vulnerability from cvelistv5
Published
2026-07-09 21:30
Modified
2026-07-10 13:37
CWE
  • CWE-272 - Least Privilege Violation
  • CWE-266 - Incorrect Privilege Assignment
Summary
A security vulnerability has been detected in TOTOLINK A3000RU, A3100R, A950RG, AC1200T10, CP450, CS185R_T10 and EX200 up to 20260906. Affected by this issue is some unknown functionality of the file /etc/boa/boa.conf of the component Web Interface. The manipulation leads to least privilege violation. The attack may be initiated remotely. The attack's complexity is rated as high. The exploitation is known to be difficult.
Impacted products
Vendor Product Version
TOTOLINK A3000RU Version: 20260906
    cpe:2.3:a:totolink:a3000ru:*:*:*:*:*:*:*:*
Create a notification for this product.
   TOTOLINK A3100R Version: 20260906
    cpe:2.3:a:totolink:a3100r:*:*:*:*:*:*:*:*
Create a notification for this product.
   TOTOLINK A950RG Version: 20260906
    cpe:2.3:a:totolink:a950rg:*:*:*:*:*:*:*:*
Create a notification for this product.
   TOTOLINK AC1200T10 Version: 20260906
    cpe:2.3:a:totolink:ac1200t10:*:*:*:*:*:*:*:*
Create a notification for this product.
   TOTOLINK CP450 Version: 20260906
    cpe:2.3:a:totolink:cp450:*:*:*:*:*:*:*:*
Create a notification for this product.
   TOTOLINK CS185R_T10 Version: 20260906
    cpe:2.3:a:totolink:cs185r_t10:*:*:*:*:*:*:*:*
Create a notification for this product.
   TOTOLINK EX200 Version: 20260906
    cpe:2.3:a:totolink:ex200:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-15271",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-10T13:37:19.484529Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-10T13:37:52.501Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:totolink:a3000ru:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Interface"
          ],
          "product": "A3000RU",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20260906"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:totolink:a3100r:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Interface"
          ],
          "product": "A3100R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20260906"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:totolink:a950rg:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Interface"
          ],
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20260906"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:totolink:ac1200t10:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Interface"
          ],
          "product": "AC1200T10",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20260906"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:totolink:cp450:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Interface"
          ],
          "product": "CP450",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20260906"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:totolink:cs185r_t10:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Interface"
          ],
          "product": "CS185R_T10",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20260906"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:totolink:ex200:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Interface"
          ],
          "product": "EX200",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20260906"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "L-14 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in TOTOLINK A3000RU, A3100R, A950RG, AC1200T10, CP450, CS185R_T10 and EX200 up to 20260906. Affected by this issue is some unknown functionality of the file /etc/boa/boa.conf of the component Web Interface. The manipulation leads to least privilege violation. The attack may be initiated remotely. The attack\u0027s complexity is rated as high. The exploitation is known to be difficult."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 7.1,
            "vectorString": "AV:N/AC:H/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-272",
              "description": "Least Privilege Violation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-09T21:30:10.629Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-377214 | TOTOLINK EX200 Web boa.conf least privilege violation",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/vuln/377214"
        },
        {
          "name": "VDB-377214 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/377214/cti"
        },
        {
          "name": "CVE-2026-15271 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-15271"
        },
        {
          "name": "Submit #852316 | TOTOLink A3000RU A3000RU V5.9c.5185 Misconfiguration in A3000RU",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/852316"
        },
        {
          "name": "Submit #852317 | TOTOLink A3100R A3100R V4.1.2cu.5050 Misconfiguration in A3100R (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/852317"
        },
        {
          "name": "Submit #852318 | TOTOLink AC1200T10 V2 AC1200T10 V2 V4.1.8cu.5207 Misconfiguration in AC1200T10 V2 (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/852318"
        },
        {
          "name": "Submit #852319 | TOTOLink CP450 CP450 V4.1.0cu.747 Misconfiguration in CP450 (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/852319"
        },
        {
          "name": "Submit #852320 | TOTOLink CS185R_T10 CS185R_T10 V5.9c.1485 Misconfiguration in CS185R_T10 (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/852320"
        },
        {
          "name": "Submit #852321 | TOTOLink EX200 EX200 V4.0.3c.7646 Misconfiguration in EX200 (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/852321"
        },
        {
          "name": "Submit #852323 | TOTOLink A950RG A950RG V5.9c.4592 Misconfiguration in A950RG (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/852323"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://app.notion.com/p/A3000RU-V5-9c-5185-37a1f5ba989080d38bb6ca58b2a98c64?source=copy_link"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-07-09T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-07-09T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-07-09T16:58:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK EX200 Web boa.conf least privilege violation"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-15271",
    "datePublished": "2026-07-09T21:30:10.629Z",
    "dateReserved": "2026-07-09T14:50:16.412Z",
    "dateUpdated": "2026-07-10T13:37:52.501Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-4496 (GCVE-0-2025-4496)
Vulnerability from cvelistv5
Published
2025-05-10 05:00
Modified
2025-05-12 19:30
CWE
Summary
A vulnerability was found in TOTOLINK T10, A3100R, A950RG, A800R, N600R, A3000RU and A810R 4.1.8cu.5241_B20210927. It has been declared as critical. This vulnerability affects the function CloudACMunualUpdate of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
References
Impacted products
Vendor Product Version
TOTOLINK T10 Version: 4.1.8cu.5241_B20210927
Create a notification for this product.
   TOTOLINK A3100R Version: 4.1.8cu.5241_B20210927
Create a notification for this product.
   TOTOLINK A950RG Version: 4.1.8cu.5241_B20210927
Create a notification for this product.
   TOTOLINK A800R Version: 4.1.8cu.5241_B20210927
Create a notification for this product.
   TOTOLINK N600R Version: 4.1.8cu.5241_B20210927
Create a notification for this product.
   TOTOLINK A3000RU Version: 4.1.8cu.5241_B20210927
Create a notification for this product.
   TOTOLINK A810R Version: 4.1.8cu.5241_B20210927
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4496",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-12T19:30:52.980508Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-12T19:30:55.738Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/1.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "T10",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.8cu.5241_B20210927"
            }
          ]
        },
        {
          "product": "A3100R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.8cu.5241_B20210927"
            }
          ]
        },
        {
          "product": "A950RG",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.8cu.5241_B20210927"
            }
          ]
        },
        {
          "product": "A800R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.8cu.5241_B20210927"
            }
          ]
        },
        {
          "product": "N600R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.8cu.5241_B20210927"
            }
          ]
        },
        {
          "product": "A3000RU",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.8cu.5241_B20210927"
            }
          ]
        },
        {
          "product": "A810R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.8cu.5241_B20210927"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "BabyShark (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK T10, A3100R, A950RG, A800R, N600R, A3000RU and A810R 4.1.8cu.5241_B20210927. It has been declared as critical. This vulnerability affects the function CloudACMunualUpdate of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In TOTOLINK T10, A3100R, A950RG, A800R, N600R, A3000RU and A810R 4.1.8cu.5241_B20210927 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion CloudACMunualUpdate der Datei /cgi-bin/cstecgi.cgi. Durch die Manipulation des Arguments FileName mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-10T05:00:10.763Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-308212 | TOTOLINK T10/A3100R/A950RG/A800R/N600R/A3000RU/A810R cstecgi.cgi CloudACMunualUpdate buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.308212"
        },
        {
          "name": "VDB-308212 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.308212"
        },
        {
          "name": "Submit #567081 | TOTOLINK T10/A3100R/A950RG/A800R/N600R/A3000RU/A810R V4.1.8cu.5241_B20210927 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.567081"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/1.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-09T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-09T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-09T14:38:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK T10/A3100R/A950RG/A800R/N600R/A3000RU/A810R cstecgi.cgi CloudACMunualUpdate buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4496",
    "datePublished": "2025-05-10T05:00:10.763Z",
    "dateReserved": "2025-05-09T12:33:38.764Z",
    "dateUpdated": "2025-05-12T19:30:55.738Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}