Refine your search

4 vulnerabilities found for 24952 MyCareLink Monitor by Medtronic

CVE-2018-10622 (GCVE-0-2018-10622)
Vulnerability from cvelistv5
Published
2018-08-10 18:00
Modified
2026-06-22 20:42
CWE
Summary
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.
Impacted products
Vendor Product Version
Medtronic 24950 MyCareLink Monitor Version: 0   < February 25, 2026
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:46:47.036Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105042",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105042"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "24950 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "lessThan": "February 25, 2026",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "24952 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "lessThan": "February 25, 2026",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Billy Rios, Jesse Young, and Jonathan Butts of Whitescope LLC reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-05-07T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eMedtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-313",
              "description": "CWE-313",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-22T20:42:16.327Z",
        "orgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
        "shortName": "Medtronic"
      },
      "references": [
        {
          "name": "105042",
          "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-8-7-18.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-219-01"
        },
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/105042"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2018/icsma-18-219-01.json"
        }
      ],
      "source": {
        "advisory": "ICSMA-18-219-01",
        "discovery": "EXTERNAL"
      },
      "title": "Medtronic MyCareLink Patient Monitor Network Credential Weakness",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:\u003c/p\u003e\n\u003cul\u003e\u003cli\u003eMaintain good physical control over the home monitor.\u003c/li\u003e\u003cli\u003eOnly use home monitors obtained directly from their healthcare \nprovider or a Medtronic representative to ensure integrity of the \nsystem.\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:\n\n\n  *  Maintain good physical control over the home monitor.\n  *  Only use home monitors obtained directly from their healthcare \nprovider or a Medtronic representative to ensure integrity of the \nsystem."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic has released additional patient focused information, at the following location:\u003c/p\u003e\n\u003cp\u003e\u003ca href=\"https://www.medtronic.com/security\"\u003ehttps://www.medtronic.com/security\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Medtronic has released additional patient focused information, at the following location:\n\n\n\n\n https://www.medtronic.com/security"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Users should follow CISA\u0027s guidance in the following areas:\u003cbr\u003e\n* \u003ca href=\"https://www.cisa.gov/news-events/news/securing-internet-things-iot\"\u003eSecuring the Internet of Things\u003c/a\u003e\u003cbr\u003e\n* \u003ca href=\"https://www.cisa.gov/news-events/news/home-network-security\"\u003eHome Network Security\u003c/a\u003e"
            }
          ],
          "value": "Users should follow CISA\u0027s guidance in the following areas:\n\n*  Securing the Internet of Things https://www.cisa.gov/news-events/news/securing-internet-things-iot \n\n*  Home Network Security https://www.cisa.gov/news-events/news/home-network-security"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-08-07T00:00:00",
          "ID": "CVE-2018-10626",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Medtronic MyCareLink 24950, 24952 Patient Monitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected product\u0027s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INSUFFICIENT VERIFICATION OF DATA AUTHENTICITY CWE-345"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105042",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105042"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10622",
    "datePublished": "2018-08-10T18:00:00.000Z",
    "dateReserved": "2018-05-01T00:00:00.000Z",
    "dateUpdated": "2026-06-22T20:42:16.327Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2018-10626 (GCVE-0-2018-10626)
Vulnerability from cvelistv5
Published
2018-08-10 18:00
Modified
2026-05-19 14:32
CWE
  • CWE-345 - Insufficient Verification of Data Authenticity
Summary
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:46:45.928Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105042",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105042"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "24950 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "24952 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Billy Rios, Jesse Young, and Jonathan Butts of Whitescope LLC reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2018-08-07T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cspan\u003eMedtronic MyCareLink Patient Monitor\u2019s update service\u0026nbsp;\u003c/span\u003edoes not sufficiently verify the authenticity of the data uploaded. An \nattacker who obtains per-product credentials from the monitor and paired\n implantable cardiac device information can potentially upload invalid \ndata to the Medtronic CareLink network.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Medtronic MyCareLink Patient Monitor\u2019s update service\u00a0does not sufficiently verify the authenticity of the data uploaded. An \nattacker who obtains per-product credentials from the monitor and paired\n implantable cardiac device information can potentially upload invalid \ndata to the Medtronic CareLink network."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-345",
              "description": "CWE-345 Insufficient Verification of Data Authenticity",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-19T14:32:21.570Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "105042",
          "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-8-7-18.html"
        },
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/105042"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-219-01"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2018/icsma-18-219-01.json"
        }
      ],
      "source": {
        "advisory": "ICSMA-18-219-01",
        "discovery": "EXTERNAL"
      },
      "title": "Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Medtronic has made server-side updates to address this insufficient \nverification vulnerability. Medtronic is \nimplementing additional server-side mitigations to enhance data \nintegrity and authenticity."
            }
          ],
          "value": "Medtronic has made server-side updates to address this insufficient \nverification vulnerability. Medtronic is \nimplementing additional server-side mitigations to enhance data \nintegrity and authenticity."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:\u003c/p\u003e\n\u003cul\u003e\u003cli\u003eMaintain good physical control over the home monitor.\u003c/li\u003e\u003cli\u003eOnly use home monitors obtained directly from their healthcare \nprovider or a Medtronic representative to ensure integrity of the \nsystem.\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation. Specifically, users should:\n\n\n  *  Maintain good physical control over the home monitor.\n  *  Only use home monitors obtained directly from their healthcare \nprovider or a Medtronic representative to ensure integrity of the \nsystem."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic has released additional patient focused information, at the following location:\u003c/p\u003e\n\u003cp\u003e\u003ca href=\"https://www.medtronic.com/security\"\u003ehttps://www.medtronic.com/security\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Medtronic has released additional patient focused information, at the following location:\n\n\n\n\n https://www.medtronic.com/security"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Users should follow CISA\u0027s guidance in the following areas:\u003cbr\u003e\n* \u003ca href=\"https://www.cisa.gov/news-events/news/securing-internet-things-iot\"\u003eSecuring the Internet of Things\u003c/a\u003e\u003cbr\u003e\n* \u003ca href=\"https://www.cisa.gov/news-events/news/home-network-security\"\u003eHome Network Security\u003c/a\u003e"
            }
          ],
          "value": "Users should follow CISA\u0027s guidance in the following areas:\n\n*  Securing the Internet of Things https://www.cisa.gov/news-events/news/securing-internet-things-iot \n\n*  Home Network Security https://www.cisa.gov/news-events/news/home-network-security"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-08-07T00:00:00",
          "ID": "CVE-2018-10626",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Medtronic MyCareLink 24950, 24952 Patient Monitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected product\u0027s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INSUFFICIENT VERIFICATION OF DATA AUTHENTICITY CWE-345"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105042",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105042"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10626",
    "datePublished": "2018-08-10T18:00:00.000Z",
    "dateReserved": "2018-05-01T00:00:00.000Z",
    "dateUpdated": "2026-05-19T14:32:21.570Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2018-8868 (GCVE-0-2018-8868)
Vulnerability from cvelistv5
Published
2018-07-02 18:00
Modified
2025-05-22 18:14
CWE
Summary
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:10:46.236Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "24950 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "24952 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Peter Morgan of Clever Security reported this vulnerability"
        }
      ],
      "datePublic": "2018-06-29T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\nMedtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor\u0027s communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor\u0027s communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-749",
              "description": "CWE-749",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-22T18:14:07.710Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-6-28-18.html"
        },
        {
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMedtronic will release several rolling over-the-air product updates that will mitigate the vulnerabilities described within this advisory. These updates will be applied to devices automatically as part of standard, reoccurring update processes. In addition, Medtronic has increased security monitoring of affected devices and related infrastructure. \u003c/span\u003e\n\n\u003c/div\u003e\n\n\u003cp\u003eMedtronic has released additional patient focused information, at the following location:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/security\"\u003ehttps://www.medtronic.com/security\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Medtronic will release several rolling over-the-air product updates that will mitigate the vulnerabilities described within this advisory. These updates will be applied to devices automatically as part of standard, reoccurring update processes. In addition, Medtronic has increased security monitoring of affected devices and related infrastructure. \n\n\n\n\n\nMedtronic has released additional patient focused information, at the following location:\n\n https://www.medtronic.com/security"
        }
      ],
      "source": {
        "advisory": "ICSMA-18-179-01",
        "discovery": "EXTERNAL"
      },
      "title": "Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic recommends users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMaintain good physical controls over the home monitor as the best mitigation to these vulnerabilities. \u0026nbsp;\u003c/li\u003e\u003cli\u003eOnly use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system. \u003c/li\u003e\u003cli\u003eReport any concerning behavior regarding their home monitor to their healthcare provider or a Medtronic representative. \u003c/li\u003e\u003c/ul\u003e\u003cp\u003eMedtronic has released additional patient focused information, at the following location:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/security\"\u003ehttps://www.medtronic.com/security\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\n  *  Maintain good physical controls over the home monitor as the best mitigation to these vulnerabilities. \u00a0\n  *  Only use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system. \n  *  Report any concerning behavior regarding their home monitor to their healthcare provider or a Medtronic representative. \n\n\nMedtronic has released additional patient focused information, at the following location:\n\n https://www.medtronic.com/security"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-06-29T00:00:00",
          "ID": "CVE-2018-8870",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Medtronic MyCareLink Patient Monitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "24950 MyCareLink Monitor, all versions, 24952 MyCareLink Monitor, all versions."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED PASSWORD CWE-259"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-8868",
    "datePublished": "2018-07-02T18:00:00.000Z",
    "dateReserved": "2018-03-20T00:00:00.000Z",
    "dateUpdated": "2025-05-22T18:14:07.710Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-8870 (GCVE-0-2018-8870)
Vulnerability from cvelistv5
Published
2018-07-02 18:00
Modified
2025-05-22 18:10
CWE
Summary
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:10:47.291Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "24950 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "24952 MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Peter Morgan of Clever Security reported this vulnerability"
        }
      ],
      "datePublic": "2018-06-29T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.\u003c/p\u003e"
            }
          ],
          "value": "Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-22T18:10:03.426Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-6-28-18.html"
        },
        {
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMedtronic will release several rolling over-the-air product updates that will mitigate the vulnerabilities described within this advisory. These updates will be applied to devices automatically as part of standard, reoccurring update processes. In addition, Medtronic has increased security monitoring of affected devices and related infrastructure. \u003c/span\u003e\n\n\u003c/div\u003e\n\n\u003cp\u003eMedtronic has released additional patient focused information, at the following location:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/security\"\u003ehttps://www.medtronic.com/security\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Medtronic will release several rolling over-the-air product updates that will mitigate the vulnerabilities described within this advisory. These updates will be applied to devices automatically as part of standard, reoccurring update processes. In addition, Medtronic has increased security monitoring of affected devices and related infrastructure. \n\n\n\n\n\nMedtronic has released additional patient focused information, at the following location:\n\n https://www.medtronic.com/security"
        }
      ],
      "source": {
        "advisory": "ICSMA-18-179-01",
        "discovery": "EXTERNAL"
      },
      "title": "Medtronic MyCareLink Patient Monitor Use of Hard-coded Password",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic recommends users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMaintain good physical controls over the home monitor as the best mitigation to these vulnerabilities. \u0026nbsp;\u003c/li\u003e\u003cli\u003eOnly use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system. \u003c/li\u003e\u003cli\u003eReport any concerning behavior regarding their home monitor to their healthcare provider or a Medtronic representative. \u003c/li\u003e\u003c/ul\u003e\u003cp\u003eMedtronic has released additional patient focused information, at the following location:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/security\"\u003ehttps://www.medtronic.com/security\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Medtronic recommends users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\n  *  Maintain good physical controls over the home monitor as the best mitigation to these vulnerabilities. \u00a0\n  *  Only use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system. \n  *  Report any concerning behavior regarding their home monitor to their healthcare provider or a Medtronic representative. \n\n\nMedtronic has released additional patient focused information, at the following location:\n\n https://www.medtronic.com/security"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-06-29T00:00:00",
          "ID": "CVE-2018-8870",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Medtronic MyCareLink Patient Monitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "24950 MyCareLink Monitor, all versions, 24952 MyCareLink Monitor, all versions."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED PASSWORD CWE-259"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-8870",
    "datePublished": "2018-07-02T18:00:00.000Z",
    "dateReserved": "2018-03-20T00:00:00.000Z",
    "dateUpdated": "2025-05-22T18:10:03.426Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}