<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://127.0.0.1:10001</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 20 Nov 2026 22:04:31 +0000</lastBuildDate>
    <item>
      <title>CVE-2026-123007 — NGINX ngx_http_v2_module vulnerability</title>
      <link>https://127.0.0.1:10001/vuln/cve-2026-123007</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; F5 NGINX Plus, F5 NGINX Open Source, Siemens Industrial Edge Cloud Device (IECD), Siemens Industrial Edge Device Kit - arm64, Siemens Industrial Edge Device Kit - x86-64, Siemens Industrial Edge Hub, Siemens Industrial Edge Management Cloud, Siemens Industrial Edge Management Pro V1, Siemens Industrial Edge Management Pro V2, Siemens Industrial Edge Management Virtual and 2 more&lt;/p&gt;
&lt;p&gt;This issue affects NGINX Plus or NGINX Open Source configurations that use HTTP/2. When NGINX processes undisclosed traffic, the flow control window can exceed the allowed threshold, potentially resulting in a heap buffer overflow typically followed by an NGINX worker segmentation fault. Additionally, attackers can execute code on systems with Address Space Layout Randomization (ASLR) disabled or when the attacker can bypass ASLR.&lt;/p&gt;
&lt;p&gt;Impact: An attacker could leverage this vulnerability to crash the NGINX worker process, corrupt its memory, or potentially execute code remotely. There is no control plane exposure; this is a data plane issue only.&lt;/p&gt;
&lt;p&gt;Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; F5 NGINX Plus, F5 NGINX Open Source, Siemens Industrial Edge Cloud Device (IECD), Siemens Industrial Edge Device Kit - arm64, Siemens Industrial Edge Device Kit - x86-64, Siemens Industrial Edge Hub, Siemens Industrial Edge Management Cloud, Siemens Industrial Edge Management Pro V1, Siemens Industrial Edge Management Pro V2, Siemens Industrial Edge Management Virtual and 2 more&lt;/p&gt;
&lt;p&gt;This issue affects NGINX Plus or NGINX Open Source configurations that use HTTP/2. When NGINX processes undisclosed traffic, the flow control window can exceed the allowed threshold, potentially resulting in a heap buffer overflow typically followed by an NGINX worker segmentation fault. Additionally, attackers can execute code on systems with Address Space Layout Randomization (ASLR) disabled or when the attacker can bypass ASLR.&lt;/p&gt;
&lt;p&gt;Impact: An attacker could leverage this vulnerability to crash the NGINX worker process, corrupt its memory, or potentially execute code remotely. There is no control plane exposure; this is a data plane issue only.&lt;/p&gt;
&lt;p&gt;Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://127.0.0.1:10001/vuln/cve-2026-123007</guid>
    </item>
  </channel>
</rss>
