Common Weakness Enumeration
CWE-788
DiscouragedAccess of Memory Location After End of Buffer
Abstraction: Base · Status: Incomplete
The product reads or writes to a buffer using an index or pointer that references a memory location after the end of the buffer.
144 vulnerabilities reference this CWE, most recent first.
CVE-2019-8280 (GCVE-0-2019-8280)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-17 01:40
VLAI
EPSS
VEX
Summary
UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.
Severity
No CVSS data available.
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
Kaspersky
CNA
References
6 references
| URL | Tags |
|---|---|
| https://ics-cert.kaspersky.com/advisories/klcert-… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
Date Public
2019-03-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.735Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:18:29.000Z",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8280",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-788: Access of Memory Location After End of Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8280",
"datePublished": "2019-03-09T00:00:00.000Z",
"dateReserved": "2019-02-12T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:40:44.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8266 (GCVE-0-2019-8266)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 23:05
VLAI
EPSS
VEX
Summary
UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208.
Severity
No CVSS data available.
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
Kaspersky
CNA
References
3 references
| URL | Tags |
|---|---|
| https://ics-cert.kaspersky.com/advisories/klcert-… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
Date Public
2019-03-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.554Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:30:20.000Z",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8266",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-788: Access of Memory Location After End of Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8266",
"datePublished": "2019-03-09T00:00:00.000Z",
"dateReserved": "2019-02-12T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:05:39.052Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8265 (GCVE-0-2019-8265)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 17:07
VLAI
EPSS
VEX
Summary
UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.
Severity
No CVSS data available.
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
Kaspersky
CNA
References
6 references
| URL | Tags |
|---|---|
| https://ics-cert.kaspersky.com/advisories/klcert-… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
Date Public
2019-03-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.842Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T11:57:30.000Z",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8265",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-788: Access of Memory Location After End of Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8265",
"datePublished": "2019-03-09T00:00:00.000Z",
"dateReserved": "2019-02-12T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:07:55.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8264 (GCVE-0-2019-8264)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 19:51
VLAI
EPSS
VEX
Summary
UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.
Severity
No CVSS data available.
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
Kaspersky
CNA
References
6 references
| URL | Tags |
|---|---|
| https://ics-cert.kaspersky.com/advisories/klcert-… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
Date Public
2019-03-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.529Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T11:55:37.000Z",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8264",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-788: Access of Memory Location After End of Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8264",
"datePublished": "2019-03-09T00:00:00.000Z",
"dateReserved": "2019-02-12T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:51:49.467Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.