Common Weakness Enumeration

CWE-489

Allowed

Active Debug Code

Abstraction: Base · Status: Draft

The product is released with debugging code still enabled or active.

97 vulnerabilities reference this CWE, most recent first.

CVE-2020-8477 (GCVE-0-2020-8477)

Vulnerability from cvelistv5 – Published: 2020-04-22 14:46 – Updated: 2024-08-04 10:03
VLAI
Title
ABB System 800xA Information Manager Remote Code Execution
Summary
The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
  • CWE-489 - Leftover Debug Code
Assigner
ABB CNA
References
Impacted products
Vendor Product Version
ABB System 800xA Information Manager Affected: 5 , ≤ 5.1 (custom)
Affected: 6.0 , ≤ 6.0.3.2 (custom)
Affected: 6.1 , < 6.1* (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:46.221Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121232\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "System 800xA Information Manager",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "5.1",
              "status": "affected",
              "version": "5",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "6.0.3.2",
              "status": "affected",
              "version": "6.0",
              "versionType": "custom"
            },
            {
              "lessThan": "6.1*",
              "status": "affected",
              "version": "6.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489 Leftover Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T14:46:23.000Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121232\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB System 800xA Information Manager Remote Code Execution",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2020-8477",
          "STATE": "PUBLIC",
          "TITLE": "ABB System 800xA Information Manager Remote Code Execution"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System 800xA Information Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "5",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6.0",
                            "version_value": "6.0.3.2"
                          },
                          {
                            "version_affected": "\u003e=",
                            "version_name": "6.1",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-489 Leftover Debug Code"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121232\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121232\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8477",
    "datePublished": "2020-04-22T14:46:23.000Z",
    "dateReserved": "2020-01-30T00:00:00.000Z",
    "dateUpdated": "2024-08-04T10:03:46.221Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8320 (GCVE-0-2020-8320)

Vulnerability from cvelistv5 – Published: 2020-06-09 19:50 – Updated: 2024-09-16 17:33
VLAI
Summary
An internal shell was included in BIOS image in some ThinkPad models that could allow escalation of privilege.
CWE
Assigner
lenovo CNA
References
Impacted products
Vendor Product Version
Lenovo BIOS Affected: various
Create a notification for this product.
Date Public
2020-06-09 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:56:28.434Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-30042"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIOS",
          "vendor": "Lenovo",
          "versions": [
            {
              "status": "affected",
              "version": "various"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Lenovo thanks Avery Mosher at SkySafe Inc."
        }
      ],
      "datePublic": "2020-06-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An internal shell was included in BIOS image in some ThinkPad models that could allow escalation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489 Leftover Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-09T19:50:34.000Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/us/en/product_security/LEN-30042"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-30042."
        }
      ],
      "source": {
        "advisory": "LEN-30042",
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2020-06-09T18:00:00.000Z",
          "ID": "CVE-2020-8320",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIOS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "various"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Lenovo thanks Avery Mosher at SkySafe Inc."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An internal shell was included in BIOS image in some ThinkPad models that could allow escalation of privilege."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-489 Leftover Debug Code"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/us/en/product_security/LEN-30042",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/us/en/product_security/LEN-30042"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-30042."
          }
        ],
        "source": {
          "advisory": "LEN-30042",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2020-8320",
    "datePublished": "2020-06-09T19:50:34.958Z",
    "dateReserved": "2020-01-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:33:07.639Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5763 (GCVE-0-2020-5763)

Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Severity
No CVSS data available.
CWE
Assigner
tenable CNA
Impacted products
Vendor Product Version
n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:39:25.821Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-43"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-47"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Grandstream HT800 Series",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.0.17.5 and below"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-29T19:06:11.000Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-43"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-47"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2020-5763",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Grandstream HT800 Series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 1.0.17.5 and below"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-489"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2020-43",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "name": "https://www.tenable.com/security/research/tra-2020-47",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2020-5763",
    "datePublished": "2020-07-29T18:51:50.000Z",
    "dateReserved": "2020-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-04T08:39:25.821Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5756 (GCVE-0-2020-5756)

Vulnerability from cvelistv5 – Published: 2020-07-17 20:16 – Updated: 2024-08-04 08:39
VLAI
Summary
Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.
Severity
No CVSS data available.
CWE
Assigner
tenable CNA
References
Impacted products
Vendor Product Version
Tenable Grandstream GWN7000 Affected: Versions 1.0.9.4 and below
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:39:25.704Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2020-41"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Grandstream GWN7000",
          "vendor": "Tenable",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 1.0.9.4 and below"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system\u0027s crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-17T20:16:27.000Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-41"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2020-5756",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Grandstream GWN7000",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 1.0.9.4 and below"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Tenable"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system\u0027s crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-489"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2020-41",
              "refsource": "CONFIRM",
              "url": "https://www.tenable.com/security/research/tra-2020-41"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2020-5756",
    "datePublished": "2020-07-17T20:16:27.000Z",
    "dateReserved": "2020-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-04T08:39:25.704Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10939 (GCVE-0-2019-10939)

Vulnerability from cvelistv5 – Published: 2020-04-14 19:50 – Updated: 2024-08-04 22:40
VLAI
Summary
A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.
Severity
No CVSS data available.
CWE
Assigner
siemens CNA
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.402Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-359303.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TIM 3V-IE (incl. SIPLUS NET variants)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8"
            }
          ]
        },
        {
          "product": "TIM 3V-IE Advanced (incl. SIPLUS NET variants)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8"
            }
          ]
        },
        {
          "product": "TIM 3V-IE DNP3 (incl. SIPLUS NET variants)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "TIM 4R-IE (incl. SIPLUS NET variants)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8"
            }
          ]
        },
        {
          "product": "TIM 4R-IE DNP3 (incl. SIPLUS NET variants)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions \u003c V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions \u003c V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions \u003c V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489: Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-14T19:50:54.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-359303.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10939",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TIM 3V-IE (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TIM 3V-IE Advanced (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TIM 3V-IE DNP3 (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TIM 4R-IE (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TIM 4R-IE DNP3 (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions \u003c V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions \u003c V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions \u003c V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-489: Active Debug Code"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-359303.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-359303.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10939",
    "datePublished": "2020-04-14T19:50:54.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.402Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-5454 (GCVE-0-2018-5454)

Vulnerability from cvelistv5 – Published: 2018-03-26 14:00 – Updated: 2024-09-16 16:57
VLAI
Summary
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime.
Severity
No CVSS data available.
CWE
  • CWE-489 - LEFTOVER DEBUG CODE CWE-489
Assigner
icscert CNA
References
Impacted products
Vendor Product Version
Philips Philips IntelliSpace Portal Affected: 8.0.x
Affected: 7.0.x
Create a notification for this product.
Date Public
2018-02-27 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:33:44.323Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
          },
          {
            "name": "103182",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103182"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Philips IntelliSpace Portal",
          "vendor": "Philips",
          "versions": [
            {
              "status": "affected",
              "version": "8.0.x"
            },
            {
              "status": "affected",
              "version": "7.0.x"
            }
          ]
        }
      ],
      "datePublic": "2018-02-27T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "LEFTOVER DEBUG CODE CWE-489",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-27T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
        },
        {
          "name": "103182",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103182"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-02-27T00:00:00",
          "ID": "CVE-2018-5454",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Philips IntelliSpace Portal",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "8.0.x"
                          },
                          {
                            "version_value": "7.0.x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Philips"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "LEFTOVER DEBUG CODE CWE-489"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
              "refsource": "CONFIRM",
              "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
            },
            {
              "name": "103182",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103182"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-5454",
    "datePublished": "2018-03-26T14:00:00.000Z",
    "dateReserved": "2018-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:57:42.535Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5259 (GCVE-0-2017-5259)

Vulnerability from cvelistv5 – Published: 2017-12-20 22:00 – Updated: 2024-08-05 14:55
VLAI
Summary
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://<device-ip-or-hostname>/adm/syscmd.asp.
Severity
No CVSS data available.
CWE
Assigner
rapid7 CNA
References
Impacted products
Vendor Product Version
Cambium Networks cnPilot Affected: 4.3.2-R4 and prior
Create a notification for this product.
Date Public
2017-12-20 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.778Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cnPilot",
          "vendor": "Cambium Networks",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.2-R4 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-12-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://\u003cdevice-ip-or-hostname\u003e/adm/syscmd.asp."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489 (Leftover Debug Code)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-20T21:57:01.000Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2017-5259",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "cnPilot",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.3.2-R4 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cambium Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://\u003cdevice-ip-or-hostname\u003e/adm/syscmd.asp."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-489 (Leftover Debug Code)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2017-5259",
    "datePublished": "2017-12-20T22:00:00.000Z",
    "dateReserved": "2017-01-09T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:55:35.778Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Build and Compilation Distribution

Remove debug code before deploying the application.

CAPEC-121: Exploit Non-Production Interfaces

An adversary exploits a sample, demonstration, test, or debug interface that is unintentionally enabled on a production system, with the goal of gleaning information or leveraging functionality that would otherwise be unavailable.

CAPEC-661: Root/Jailbreak Detection Evasion via Debugging

An adversary inserts a debugger into the program entry point of a mobile application to modify the application binary, with the goal of evading Root/Jailbreak detection. Mobile device users often Root/Jailbreak their devices in order to gain administrative control over the mobile operating system and/or to install third-party mobile applications that are not provided by authorized application stores (e.g. Google Play Store and Apple App Store). Rooting/Jailbreaking a mobile device also provides users with access to system debuggers and disassemblers, which can be leveraged to exploit applications by dumping the application's memory at runtime in order to remove or bypass signature verification methods. This further allows the adversary to evade Root/Jailbreak detection mechanisms, which can result in execution of administrative commands, obtaining confidential data, impersonating legitimate users of the application, and more.