Common Weakness Enumeration

CWE-316

Allowed

Cleartext Storage of Sensitive Information in Memory

Abstraction: Variant · Status: Draft

The product stores sensitive information in cleartext in memory.

36 vulnerabilities reference this CWE, most recent first.

CVE-2024-24915 (GCVE-0-2024-24915)

Vulnerability from cvelistv5 – Published: 2025-06-29 12:02 – Updated: 2025-06-30 13:32
VLAI
Title
SmartConsole Sensitive Credential Exposure via Memory Dump
Summary
Credentials are not cleared from memory after being used. A user with Administrator permissions can execute memory dump for SmartConsole process and fetch them.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-30 13:14 UTC
CWE
  • CWE-316 - The product stores sensitive information in cleartext in memory.
Assigner
References
Impacted products
Vendor Product Version
checkpoint Check Point SmartConsole Affected: Check Point SmartConsole versions R81.10, R81.20, R82
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-24915",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-30T13:14:08.984786Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-30T13:32:15.417Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Check Point SmartConsole",
          "vendor": "checkpoint",
          "versions": [
            {
              "status": "affected",
              "version": "Check Point SmartConsole versions R81.10, R81.20, R82"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Credentials are not cleared from memory after being used. A user with Administrator permissions can execute memory dump for SmartConsole process and fetch them."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "The product stores sensitive information in cleartext in memory.",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-29T12:02:41.126Z",
        "orgId": "897c38be-0345-43cd-b6cf-fe179e0c4f45",
        "shortName": "checkpoint"
      },
      "references": [
        {
          "url": "https://support.checkpoint.com/results/sk/sk183545"
        }
      ],
      "title": "SmartConsole Sensitive Credential Exposure via Memory Dump"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "897c38be-0345-43cd-b6cf-fe179e0c4f45",
    "assignerShortName": "checkpoint",
    "cveId": "CVE-2024-24915",
    "datePublished": "2025-06-29T12:02:41.126Z",
    "dateReserved": "2024-02-01T15:19:26.278Z",
    "dateUpdated": "2025-06-30T13:32:15.417Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-9203 (GCVE-0-2024-9203)

Vulnerability from cvelistv5 – Published: 2024-09-26 17:00 – Updated: 2024-09-26 18:23
VLAI
Title
Enpass Password Manager sensitive information in memory
Summary
A vulnerability, which was classified as problematic, has been found in Enpass Password Manager up to 6.9.5 on Windows. This issue affects some unknown processing. The manipulation leads to cleartext storage of sensitive information in memory. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation is known to be difficult. Upgrading to version 6.10.1 is able to address this issue. It is recommended to upgrade the affected component.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-26 17:41 UTC
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
VulDB CNA
References
Impacted products
Vendor Product Version
Enpass Password Manager Affected: 6.9.0
Affected: 6.9.1
Affected: 6.9.2
Affected: 6.9.3
Affected: 6.9.4
Affected: 6.9.5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9203",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-26T17:41:08.408118Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-26T18:23:44.666Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Password Manager",
          "vendor": "Enpass",
          "versions": [
            {
              "status": "affected",
              "version": "6.9.0"
            },
            {
              "status": "affected",
              "version": "6.9.1"
            },
            {
              "status": "affected",
              "version": "6.9.2"
            },
            {
              "status": "affected",
              "version": "6.9.3"
            },
            {
              "status": "affected",
              "version": "6.9.4"
            },
            {
              "status": "affected",
              "version": "6.9.5"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "efchatz (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as problematic, has been found in Enpass Password Manager up to 6.9.5 on Windows. This issue affects some unknown processing. The manipulation leads to cleartext storage of sensitive information in memory. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation is known to be difficult. Upgrading to version 6.10.1 is able to address this issue. It is recommended to upgrade the affected component."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Enpass Password Manager bis 6.9.5 f\u00fcr Windows entdeckt. Sie wurde als problematisch eingestuft. Es geht hierbei um eine nicht n\u00e4her spezifizierte Funktion. Durch Manipulieren mit unbekannten Daten kann eine cleartext storage of sensitive information in memory-Schwachstelle ausgenutzt werden. Umgesetzt werden muss der Angriff lokal. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Die Ausnutzbarkeit gilt als schwierig. Ein Aktualisieren auf die Version 6.10.1 vermag dieses Problem zu l\u00f6sen. Als bestm\u00f6gliche Massnahme wird das Einspielen eines Upgrades empfohlen."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 1,
            "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-26T17:00:07.180Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-278561 | Enpass Password Manager sensitive information in memory",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.278561"
        },
        {
          "name": "VDB-278561 | CTI Indicators (IOB, IOC, TTP)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.278561"
        },
        {
          "name": "Submit #411207 | Enpass Password Manager Windows 10 Cleartext Storage of Sensitive Information in Memory",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.411207"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://www.enpass.io/release-notes/windows-10-desktop/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-09-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-09-26T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-09-26T14:51:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Enpass Password Manager sensitive information in memory"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-9203",
    "datePublished": "2024-09-26T17:00:07.180Z",
    "dateReserved": "2024-09-26T12:45:56.775Z",
    "dateUpdated": "2024-09-26T18:23:44.666Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-44153 (GCVE-0-2023-44153)

Vulnerability from cvelistv5 – Published: 2023-09-27 12:00 – Updated: 2024-09-23 19:26
VLAI
Summary
Sensitive information disclosure due to cleartext storage of sensitive information in memory. The following products are affected: Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 35979.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-23 19:26 UTC
CWE
Assigner
Acronis CNA
References
Impacted products
Vendor Product Version
Acronis Acronis Cyber Protect 15 Affected: unspecified , < 35979 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:59:51.619Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "SEC-1994",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://security-advisory.acronis.com/advisories/SEC-1994"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-44153",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-23T19:26:40.511726Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-23T19:26:52.210Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux",
            "macOS",
            "Windows"
          ],
          "product": "Acronis Cyber Protect 15",
          "vendor": "Acronis",
          "versions": [
            {
              "lessThan": "35979",
              "status": "affected",
              "version": "unspecified",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Sensitive information disclosure due to cleartext storage of sensitive information in memory. The following products are affected: Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 35979."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 2.2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-27T12:00:09.210Z",
        "orgId": "73dc0fef-1c66-4a72-9d2d-0a0f4012c175",
        "shortName": "Acronis"
      },
      "references": [
        {
          "name": "SEC-1994",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://security-advisory.acronis.com/advisories/SEC-1994"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "73dc0fef-1c66-4a72-9d2d-0a0f4012c175",
    "assignerShortName": "Acronis",
    "cveId": "CVE-2023-44153",
    "datePublished": "2023-09-27T12:00:09.210Z",
    "dateReserved": "2023-09-26T13:09:58.802Z",
    "dateUpdated": "2024-09-23T19:26:52.210Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-40724 (GCVE-0-2023-40724)

Vulnerability from cvelistv5 – Published: 2023-09-12 09:32 – Updated: 2025-02-27 20:56
VLAI
Summary
A vulnerability has been identified in QMS Automotive (All versions < V12.39). User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impersonation.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-26 21:51 UTC
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
siemens CNA
Impacted products
Vendor Product Version
Siemens QMS Automotive Affected: All versions < V12.39
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:38:51.205Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-40724",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:51:53.746180Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T20:56:12.283Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "QMS Automotive",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.39"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impersonation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:32:24.395Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-40724",
    "datePublished": "2023-09-12T09:32:24.395Z",
    "dateReserved": "2023-08-21T10:57:08.485Z",
    "dateUpdated": "2025-02-27T20:56:12.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-23349 (GCVE-0-2023-23349)

Vulnerability from cvelistv5 – Published: 2024-03-22 16:15 – Updated: 2025-04-10 20:10
VLAI
Summary
Kaspersky has fixed a security issue in Kaspersky Password Manager (KPM) for Windows that allowed a local user to recover the auto-filled credentials from a memory dump when the KPM extension for Google Chrome is used. To exploit the issue, an attacker must trick a user into visiting a login form of a website with the saved credentials, and the KPM extension must autofill these credentials. The attacker must then launch a malware module to steal those specific credentials.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-03-25 16:49 UTC
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
Kaspersky CNA
References
Impacted products
Vendor Product Version
Kaspersky Kaspersky Password Manager for Windows Affected: * , < 24.0.0.427 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-23349",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-25T16:49:20.375552Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T20:10:58.369Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:28:40.854Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "Advisory issued on March 18, 2024",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://support.kaspersky.com/vulnerability/list-of-advisories/12430#180324"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Kaspersky Password Manager for Windows",
          "vendor": "Kaspersky",
          "versions": [
            {
              "lessThan": "24.0.0.427",
              "status": "affected",
              "version": "*",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Efstratios Chatzoglou"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Zisis Tsiatsikas"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Vyron Kampourakis"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Kaspersky has fixed a security issue in Kaspersky Password Manager (KPM) for Windows that allowed a local user to recover the auto-filled credentials from a memory dump when the KPM extension for Google Chrome is used. To exploit the issue, an attacker must trick a user into visiting a login form of a website with the saved credentials, and the KPM extension must autofill these credentials. The attacker must then launch a malware module to steal those specific credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-27T11:51:13.706Z",
        "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
        "shortName": "Kaspersky"
      },
      "references": [
        {
          "name": "Advisory issued on March 18, 2024",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://support.kaspersky.com/vulnerability/list-of-advisories/12430#180324"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Install Kaspersky Password Manager (KPM) version 24.0.0.427 or later using the following url: https://support.kaspersky.com/help/KPM/Win24.0/en-US/85241.htm"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-18T00:00:00.000Z",
          "value": "Advisory published by Kaspersky"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
    "assignerShortName": "Kaspersky",
    "cveId": "CVE-2023-23349",
    "datePublished": "2024-03-22T16:15:55.200Z",
    "dateReserved": "2023-01-11T20:11:14.512Z",
    "dateUpdated": "2025-04-10T20:10:58.369Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-3762 (GCVE-0-2023-3762)

Vulnerability from cvelistv5 – Published: 2023-07-19 06:31 – Updated: 2024-08-02 07:08
VLAI
Title
Intergard SGS sensitive information in memory
Summary
A vulnerability was found in Intergard SGS 8.7.0. It has been classified as problematic. This affects an unknown part. The manipulation leads to cleartext storage of sensitive information in memory. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-234447. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
VulDB CNA
References
URL Tags
https://vuldb.com/?id.234447 vdb-entrytechnical-description
https://vuldb.com/?ctiid.234447 signaturepermissions-required
https://youtu.be/Ee2KU-T_0pI exploitmedia-coverage
Impacted products
Vendor Product Version
Intergard SGS Affected: 8.7.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:08:50.127Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.234447"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.234447"
          },
          {
            "tags": [
              "exploit",
              "media-coverage",
              "x_transferred"
            ],
            "url": "https://youtu.be/Ee2KU-T_0pI"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SGS",
          "vendor": "Intergard",
          "versions": [
            {
              "status": "affected",
              "version": "8.7.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "hiagomoura (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Intergard SGS 8.7.0. It has been classified as problematic. This affects an unknown part. The manipulation leads to cleartext storage of sensitive information in memory. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-234447. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Intergard SGS 8.7.0 ausgemacht. Sie wurde als problematisch eingestuft. Es geht dabei um eine nicht klar definierte Funktion. Durch Manipulation mit unbekannten Daten kann eine cleartext storage of sensitive information in memory-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316 Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-23T17:36:24.565Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.234447"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.234447"
        },
        {
          "tags": [
            "exploit",
            "media-coverage"
          ],
          "url": "https://youtu.be/Ee2KU-T_0pI"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-07-18T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-07-18T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-07-18T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-08-09T16:04:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Intergard SGS sensitive information in memory"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-3762",
    "datePublished": "2023-07-19T06:31:03.558Z",
    "dateReserved": "2023-07-18T19:29:30.097Z",
    "dateUpdated": "2024-08-02T07:08:50.127Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-46141 (GCVE-0-2022-46141)

Vulnerability from cvelistv5 – Published: 2023-12-12 11:25 – Updated: 2024-11-25 21:17
VLAI
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-25 21:17 UTC
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
siemens CNA
Impacted products
Vendor Product Version
Siemens SIMATIC STEP 7 (TIA Portal) Affected: All versions < V19
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.267Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-46141",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-25T21:17:05.789021Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-25T21:17:26.263Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 (TIA Portal)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V19"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions \u003c V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-12T11:25:26.583Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46141",
    "datePublished": "2023-12-12T11:25:26.583Z",
    "dateReserved": "2022-11-28T16:50:58.483Z",
    "dateUpdated": "2024-11-25T21:17:26.263Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-33918 (GCVE-0-2022-33918)

Vulnerability from cvelistv5 – Published: 2022-10-12 19:25 – Updated: 2025-05-15 15:35
VLAI
Summary
Dell GeoDrive, Versions 2.1 - 2.2, contains an information disclosure vulnerability. An authenticated non-admin user could potentially exploit this vulnerability and gain access to sensitive information.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-15 15:35 UTC
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
dell CNA
References
Impacted products
Vendor Product Version
Dell GeoDrive Affected: unspecified , < 2.2 (custom)
Create a notification for this product.
Date Public
2022-09-22 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:09:22.840Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000203632"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-33918",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-15T15:35:02.186409Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-15T15:35:09.852Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GeoDrive",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-09-22T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell GeoDrive, Versions 2.1 - 2.2, contains an information disclosure vulnerability. An authenticated non-admin user could potentially exploit this vulnerability and gain access to sensitive information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-12T00:00:00.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "url": "https://www.dell.com/support/kbdoc/000203632"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-33918",
    "datePublished": "2022-10-12T19:25:42.464Z",
    "dateReserved": "2022-06-17T00:00:00.000Z",
    "dateUpdated": "2025-05-15T15:35:09.852Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29832 (GCVE-0-2022-29832)

Vulnerability from cvelistv5 – Published: 2022-11-24 23:37 – Updated: 2025-04-25 17:36
VLAI
Summary
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-25 17:36 UTC
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.792Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-29832",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-25T17:36:25.700934Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-25T17:36:39.764Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.015R and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Developer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "8.40S and later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting."
            }
          ],
          "value": "Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316 Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-31T06:40:22.640Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29832",
    "datePublished": "2022-11-24T23:37:41.044Z",
    "dateReserved": "2022-04-27T20:47:43.445Z",
    "dateUpdated": "2025-04-25T17:36:39.764Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-0835 (GCVE-0-2022-0835)

Vulnerability from cvelistv5 – Published: 2022-04-11 19:38 – Updated: 2025-04-16 17:56
VLAI
Title
AVEVA System Platform Cleartext Storage of Sensitive Information in Memory
Summary
AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 17:29 UTC
CWE
  • CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
icscert CNA
References
Impacted products
Vendor Product Version
AVEVA AVEVA System Platform Affected: 5.59 2020 R2 P01
Affected: 2020 R2S
Affected: 2020
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:40:04.450Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-0835",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:29:59.891448Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:56:24.023Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AVEVA System Platform",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "affected",
              "version": "5.59 2020 R2 P01"
            },
            {
              "status": "affected",
              "version": "2020 R2S"
            },
            {
              "status": "affected",
              "version": "2020"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Noam Moshe of Claroty and Ilya Karpov, Evgeniy Druzhinin, and Konstantin Kondratev of Rostelecom-Solar reported this vulnerability to AVEVA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-11T19:38:30.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "AVEVA recommends users of affected versions upgrade to one of the versions listed below and apply the corresponding security update:\n\u2022\tAVEVA System Platform 2020 R2 P01 and AVEVA System Platform 2020 R2: update to AVEVA System Platform 2020 R2 SP1\n\u2022\tAVEVA System Platform 2020: update to AVEVA System Platform 2020 P01\n\nFor more information on this issue, including security updates, please see Security Bulletin AVEVA-2021-007\n"
        }
      ],
      "source": {
        "advisory": "ICSA-22-067-02",
        "discovery": "EXTERNAL"
      },
      "title": "AVEVA System Platform Cleartext Storage of Sensitive Information in Memory",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2022-0835",
          "STATE": "PUBLIC",
          "TITLE": "AVEVA System Platform Cleartext Storage of Sensitive Information in Memory"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AVEVA System Platform",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "5.59",
                            "version_value": "2020 R2 P01"
                          },
                          {
                            "version_value": "2020 R2S"
                          },
                          {
                            "version_value": "2020"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AVEVA"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Noam Moshe of Claroty and Ilya Karpov, Evgeniy Druzhinin, and Konstantin Kondratev of Rostelecom-Solar reported this vulnerability to AVEVA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-316: Cleartext Storage of Sensitive Information in Memory"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02"
            },
            {
              "name": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "AVEVA recommends users of affected versions upgrade to one of the versions listed below and apply the corresponding security update:\n\u2022\tAVEVA System Platform 2020 R2 P01 and AVEVA System Platform 2020 R2: update to AVEVA System Platform 2020 R2 SP1\n\u2022\tAVEVA System Platform 2020: update to AVEVA System Platform 2020 P01\n\nFor more information on this issue, including security updates, please see Security Bulletin AVEVA-2021-007\n"
          }
        ],
        "source": {
          "advisory": "ICSA-22-067-02",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-0835",
    "datePublished": "2022-04-11T19:38:30.000Z",
    "dateReserved": "2022-03-02T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:56:24.023Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

No mitigation information available for this CWE.