Common Weakness Enumeration

CWE-1240

Allowed

Use of a Cryptographic Primitive with a Risky Implementation

Abstraction: Base · Status: Draft

To fulfill the need for a cryptographic primitive, the product implements a cryptographic algorithm using a non-standard, unproven, or disallowed/non-compliant cryptographic implementation.

22 vulnerabilities reference this CWE, most recent first.

CVE-2024-0220 (GCVE-0-2024-0220)

Vulnerability from cvelistv5 – Published: 2024-02-22 10:15 – Updated: 2024-09-19 17:24
VLAI
Title
B&R products use insufficient communication encryption
Summary
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-02-22 16:23 UTC
CWE
  • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
  • CWE-319 - Cleartext Transmission of Sensitive Information
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
ABB CNA
Impacted products
Vendor Product Version
B&R Industrial Automation Automation Studio Affected: 4.0 , < 4.6 (patch)
Create a notification for this product.
B&R Industrial Automation Technology Guarding Affected: 1.0.0 , < 1.4.0 (patch)
Create a notification for this product.
br-automation automation_studio Affected: 4.0 , < 4.6 (custom)
    cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-02-22 10:10
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:15.976Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "automation_studio",
            "vendor": "br-automation",
            "versions": [
              {
                "lessThan": "4.6",
                "status": "affected",
                "version": "4.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0220",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-22T16:23:26.378691Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T16:52:09.908Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Upgrade Service"
          ],
          "product": "Automation Studio",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "4.6",
              "status": "affected",
              "version": "4.0",
              "versionType": "patch"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Technology Guarding",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "1.4.0",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "patch"
            }
          ]
        }
      ],
      "datePublic": "2024-02-22T10:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "B\u0026amp;R Automation Studio Upgrade Service and B\u0026amp;R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.\n\n\u003cbr\u003e"
            }
          ],
          "value": "B\u0026R Automation Studio Upgrade Service and B\u0026R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1240",
              "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-19T17:24:51.723Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"
        }
      ],
      "source": {
        "advisory": "2023-P019",
        "discovery": "INTERNAL"
      },
      "title": "B\u0026R products use insufficient communication encryption",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-0220",
    "datePublished": "2024-02-22T10:15:44.750Z",
    "dateReserved": "2024-01-03T15:46:41.224Z",
    "dateUpdated": "2024-09-19T17:24:51.723Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-51392 (GCVE-0-2023-51392)

Vulnerability from cvelistv5 – Published: 2024-02-23 16:12 – Updated: 2025-04-22 16:15
VLAI
Title
Silicon Labs EFR32xxx parts with classic key storage do not use hardware accelerated AES-CCM
Summary
Ember ZNet between v7.2.0 and v7.4.0 used software AES-CCM instead of integrated hardware cryptographic accelerators, potentially increasing risk of electromagnetic and differential power analysis sidechannel attacks.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-25 17:59 UTC
CWE
  • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
Assigner
Silabs CNA
References
Impacted products
Vendor Product Version
silabs.com Ember ZNet SDK Affected: 7.2.0 , < 7.4.0 (7.x)
Create a notification for this product.
Date Public
2024-02-15 17:32
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-51392",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-25T17:59:54.322798Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-22T16:15:25.335Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:32:09.157Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://community.silabs.com/068Vm000001BKm6"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "packageName": "Ember ZNet SDK",
          "platforms": [
            "32 bit",
            "ARM"
          ],
          "product": "Ember ZNet SDK",
          "repo": "https://github.com/SiliconLabs/gecko_sdk/releases",
          "vendor": "silabs.com",
          "versions": [
            {
              "lessThan": "7.4.0",
              "status": "affected",
              "version": "7.2.0",
              "versionType": "7.x"
            }
          ]
        }
      ],
      "datePublic": "2024-02-15T17:32:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Ember ZNet between v7.2.0 and v7.4.0 used software AES-CCM instead of integrated hardware cryptographic accelerators, potentially increasing risk of electromagnetic and differential power analysis sidechannel attacks."
            }
          ],
          "value": "Ember ZNet between v7.2.0 and v7.4.0 used software AES-CCM instead of integrated hardware cryptographic accelerators, potentially increasing risk of electromagnetic and differential power analysis sidechannel attacks."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-622",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-622 Electromagnetic Side-Channel Attack"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1240",
              "description": "CWE-1240 Use of a Cryptographic Primitive with a Risky Implementation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-27T15:41:55.288Z",
        "orgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
        "shortName": "Silabs"
      },
      "references": [
        {
          "url": "https://community.silabs.com/068Vm000001BKm6"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Silicon Labs EFR32xxx parts with classic key storage do not use hardware accelerated AES-CCM",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
    "assignerShortName": "Silabs",
    "cveId": "CVE-2023-51392",
    "datePublished": "2024-02-23T16:12:41.261Z",
    "dateReserved": "2023-12-18T20:56:24.812Z",
    "dateUpdated": "2025-04-22T16:15:25.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation MIT-55
Requirements

Require compliance with the strongest-available recommendations from trusted parties, and require that compliance must be kept up-to-date, since recommendations evolve over time. For example, US government systems require FIPS 140-3 certification, which supersedes FIPS 140-2 [REF-1192] [REF-267].

Mitigation
Architecture and Design

Ensure that the architecture/design uses the strongest-available primitives and algorithms from trusted parties. For example, US government systems require FIPS 140-3 certification, which supersedes FIPS 140-2 [REF-1192] [REF-267].

Mitigation MIT-54
Architecture and Design

Do not develop custom or private cryptographic algorithms. They will likely be exposed to attacks that are well-understood by cryptographers. As with all cryptographic mechanisms, the source code should be available for analysis. If the algorithm may be compromised when attackers find out how it works, then it is especially weak.

Mitigation
Architecture and Design

Try not to use cryptographic algorithms in novel ways or with new modes of operation even when you "know" it is secure. For example, using SHA-2 chaining to create a 1-time pad for encryption might sound like a good idea, but one should not do this.

Mitigation MIT-52
Architecture and Design

Ensure that the design can replace one cryptographic primitive or algorithm with another in the next generation ("cryptographic agility"). Where possible, use wrappers to make the interfaces uniform. This will make it easier to upgrade to stronger algorithms. This is especially important for hardware, which can be more difficult to upgrade quickly than software; design the hardware at a replaceable block level.

Mitigation
Architecture and Design

Do not use outdated or non-compliant cryptography algorithms. Some older algorithms, once thought to require a billion years of computing time, can now be broken in days or hours. This includes MD4, MD5, SHA1, DES, and other algorithms that were once regarded as strong [REF-267].

Mitigation
Architecture and Design Implementation

Do not use a linear-feedback shift register (LFSR) or other legacy methods as a substitute for an accepted and standard Random Number Generator.

Mitigation
Architecture and Design Implementation

Do not use a checksum as a substitute for a cryptographically generated hash.

Mitigation
Architecture and Design

Strategy: Libraries or Frameworks

Use a vetted cryptographic library or framework. Industry-standard implementations will save development time and are more likely to avoid errors that can occur during implementation of cryptographic algorithms. However, the library/framework could be used incorrectly during implementation.

Mitigation
Architecture and Design Implementation

When using industry-approved techniques, use them correctly. Don't cut corners by skipping resource-intensive steps (CWE-325). These steps are often essential for the prevention of common attacks.

Mitigation
Architecture and Design Implementation

Do not store keys in areas accessible to untrusted agents. Carefully manage and protect the cryptographic keys (see CWE-320). If the keys can be guessed or stolen, then the strength of the cryptography algorithm is irrelevant.

CAPEC-97: Cryptanalysis

Cryptanalysis is a process of finding weaknesses in cryptographic algorithms and using these weaknesses to decipher the ciphertext without knowing the secret key (instance deduction). Sometimes the weakness is not in the cryptographic algorithm itself, but rather in how it is applied that makes cryptanalysis successful. An attacker may have other goals as well, such as: Total Break (finding the secret key), Global Deduction (finding a functionally equivalent algorithm for encryption and decryption that does not require knowledge of the secret key), Information Deduction (gaining some information about plaintexts or ciphertexts that was not previously known) and Distinguishing Algorithm (the attacker has the ability to distinguish the output of the encryption (ciphertext) from a random permutation of bits).